LCD
GRAPHIC
FACTORY
FUNCTION
DISPLAY
SETTING
DESCRIPTION
SETTING
6-10
NOTES:
– When X1 – CM, X2 – CM, and X3 –
CM are all OFF, frequency reference is
set by keypad (/\ \/ keys) or by the
analog inputs per Function Code 00 setting.
– A setting in Function Code 20 through 26
above the maximum frequency in Function
Code 02 is NOT possible.
– When Function Code 65 equals 1, 2, or 3,
pattern operation is active.
* 27
DBR OL
DYNAMIC BRAKING RESISTOR OVERLOAD
0
The drive has a pre-programmed electronic (15 Hp and UP)
thermal overload protection function for the
1
dynamic braking resistors for Drives rated (UP TO 10 Hp)
10 Hp and below. Drives rated 15 Hp and
above, or for non-standard braking resistor
packages, use a thermal overload sensing
device.
0:
Inactive (15 Hp and greater or non-standard
DB resistors)
1:
Active (for internal braking resistor, up to
10 Hp.
MULTI STEP FREQUENCIES (Cont'd)
Output
Frequency
X1-CM
X2-CM
X3-CM
FWD-CM
t
Analog
Digital
Speed
1
Speed
2
Speed
4
Speed
5
Speed
6
Speed
7
Speed
3
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com