background image

D. Luminaires with primary disconnects (outlet box  hanging hardware Figure 7, rigid pendant

hardware Figure 8 and flexible pendant hanging hardware Figure 9)

1. Remove cover plate(s) and attach hanging hardware to pendant/conduit and tighten set screw.

Figure 7

Figure 8

Figure 9

CAUTION

Risk of burn

Allow lamp/fixture to cool before handling

Figure 10

Cover

Wireform

Bird  Shield

10  Inches

(254 mm)

WARNING

Risk of burn

Do not touch operating luminaire

2. Feed supply wire through conduit and into disconnect housing.  Make necessary wire connections.
3. Slide the extrusion attached to the luminaire completely into the hanger extrusion.  Replace

cover plate.
(Cover plate is necessary to lock luminaire into place on the hardware, cover electrical

connections and, if so equipped, seal unit from water.)

WIRING

Make all electrical connections in accordance with the National Electrical Code and any applicable

local code requirements.

Verify that supply voltage is correct by comparing it to nameplate.

For Rigid Pendant and Flexible Pendant mounting, customer’s supply connections must be above the

Nomex Wire Shield  (Reference:  

B.  Rigid Pendant Mounting

, Note 2 and 5.)

IF SINGLE VOLTAGE

 – All single voltage/wattage ballasts are pre-wired such that user need only

connect supply conductors.

IF MULTIVOLT – (120/208/240/277)

 Units are pre-wired for 277.  To change voltage of unit to a voltage

other 277 volts:

Disconnect incoming power lead from 277-volt  ballast lead.  Insulate the end of the 277-volt

ballast lead.  Reconnect incoming power lead to the ballast lead marked with the correct voltage.

Incoming power lead should be stripped back 3/8” and firmly inserted in the plastic termination block

on the desired voltage ballast lead.

LAMPS

Use only lamps specified on nameplate.  Observe lamp manufacturer’s recommendations and

restrictions on lamp operation, particularly ballast type, burning position, etc.

Lamp Tightness- Mogul Base Lamp:

  Lamp should be securely inserted to the NEMA-EEI specified

torque of 35 inch-pounds, which is best achieved by very firmly tightening to insure application of sufficient

torque.

Tightening must be sufficient to fully depress and load the center contact of the socket.

Lamp Tightness- Medium Base Lamp:

  Lamp should be tightened to a light firmness sufficient to

depress the center contact of the socket.

Switched Quartz- Units equipped for switched quartz operation will have the socket installed in the

reflector.  Install quartz lamp.

Figure 6

Set Screw

Screws

Hub

6  Inches

(152 mm)

Gasket

Cover

MAINTENANCE

Cleaning

Occasionally it will be necessary for the refractor to be cleaned to maintain appearance and light

levels.  The frequency of cleaning will be dependent on the ambient dirt level and minimum light level

required.  Refractor and housing should be washed with a solution of warm water and mild household

detergent, rinsed with clean water and wiped dry.  Should the interior optical assembly become dirty, clean

the reflector and interior of refractor as described above.  Replace gasket if damaged.

Lamp Replacement

Light output of a luminaire is also dependent on the age of the lamp.  In applications where light level

is critical it may be desirable to replace lamps before the burn out.  Consult lamp manufacturer’s data for

lamp replacement frequency and other safety issues.

Replace blackened lamps immediately.

Summary of Contents for Garage Guardian

Page 1: ...ned by loosening three lens screws then loosening reflector screws and removing reflector The locking screw must be backed out approximately one half inch Figure 3 B Rigid Pendant Mounting 1 Loosen three lens screws and remove refractor and refractor ring from luminaire housing 2 Loosen reflector screws remove reflector Remove nomex wire shield 3 Thread pendant conduit into top housing Figure4 or ...

Page 2: ... Incoming power lead should be stripped back 3 8 and firmly inserted in the plastic termination block on the desired voltage ballast lead LAMPS Use only lamps specified on nameplate Observe lamp manufacturer s recommendations and restrictions on lamp operation particularly ballast type burning position etc Lamp Tightness Mogul Base Lamp Lamp should be securely inserted to the NEMA EEI specified to...

Page 3: ...ssez le conduit de suspension dans le haut du carter Figure 4 ou le moyeu de montage Figure 6 et serrez l écrou de blocage 4 Passez les fils dans le conduit de suspension et sortez les d environ 15 cm dans le carter puis réalisez les connexions nécessaires voir la section sur le câblage Branchez le fil de terre de l arrivée d alimentation sur le fil vert du luminaire Figure4 Figure5 Écrou de bloca...

Page 4: ...POULES N utilisezquedesmodèlesd ampoulesspécifiéssurlaplaquesignalétique Suivezlesrecommandations et les restrictions de fonctionnement de son fabricant en particulier concernant type de ballast position d allumage etc Serrage d ampoule Culot Mogul L ampoule doit être bien insérée au couple de serrage spécifié NEMA EEI de 35 pied livres ce qui s obtient en serrant très fermement à la main Le serra...

Reviews: