background image

2

GROUNDING REQUIREMENTS

Improper connection of the equipment

grounding conductor can result in a risk of electrical shock. Check
with a licensed electrician if you are in doubt as to whether the
appliance is properly grounded.
1.

The washer 

MUST

 be grounded. In the event of malfunction

or breakdown, grounding will reduce the risk of electrical
shock by a path of least resistance for electrical current.

2.

Since your washer is equipped with a power supply cord
having an equipment-grounding conductor and a grounding
plug, the plug 

MUST

 be plugged into an appropriate, copper

wired receptacle that is properly installed and grounded in
accordance with all local codes and ordinances or in the
absence of local codes, with the National Electrical Codes,
ANSI/NFPA 70 (latest edition). If in doubt, call a licensed
electrician. 

DO NOT

 cut off or alter the grounding prong on

the power supply cord. In situations where a two-slot
receptacle is present, it is the owner’s responsibility to have
a licensed electrician replace it with a 

properly grounded

three prong grounding type receptacle.

WATER SUPPLY REQUIREMENTS

Hot and cold water faucets 

MUST

 be installed within 42 inches

(107 cm) of your washer’s water inlet. The faucets 

MUST

 be 3/

4 inch (1.9 cm) garden hose type so inlet hoses can be
connected. Water pressure 

MUST

 be between 30 and 120

pounds per square inch (maximum unbalance pressure, hot vs.
cold, 10 psi.) Your water department can advise you of your
water pressure. The hot water temperature should be about
140 degrees F (60 degrees C).

DRAIN REQUIREMENTS

1.

Drain capable of eliminating 17 gals (64.3 L) per minute.

2.

A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.

3.

The standpipe height above the floor should be:

Minimum height:

24 in. (61 cm)

Maximum height:

96 in. (244 cm)

NOTE:

Drain hose attached to the washer can reach a 90 in. (229
cm) high standpipe. For higher standpipe,   use hose P/N

134369410

, available from an authorized parts distributor.

PRE-INSTALLATION REQUIREMENTS

Tools Required for Installation:

1. Phillips screwdriver
2. 10 mm socket with ratchet.
3. Channel-lock adjustable pliers.
4. Carpenter’s level.

ELECTRICAL REQUIREMENTS

CIRCUIT

 - Individual, properly polarized and grounded 15 amp.

branch circuit fused with 15 amp. time delay fuse or circuit
breaker.

POWER SUPPLY

 - 2 wire, with ground, 120 volt, single phase,

60 Hz, Alternating Current. 

NOTE:

 The use of this washer with

power created by gas powered generators, solar powered
generators, wind powered generators or any other generator
other than the local utility company is not recommended.

OUTLET RECEPTACLE

 - Properly grounded 3-prong receptacle

to be located so the power supply cord is accessible when the
washer is in an installed position.

24 in.

(61 cm)

Min.

96 in.

(244 cm)

Max.

BACK

NOTE: 

GFI (Ground Fault Interrupter) receptacle is not required.

Before beginning installation, carefully read these instructions.
This will simplify the installation and ensure the  washer is installed
correctly and safely. Leave these instructions near the washer
after installation for future reference.

NOTE: The electrical service to the washer must conform with
local codes and ordinances and the latest edition of the National
Electrical Code, ANSI/NFPA 70.

  

For your safety the information in this manual

must be followed to minimize the risk of fire or explosion or to
prevent property damage, personal injury or loss of life.

- Do not store or use gasoline or other flammable vapors and

liquid in the vicinity of this or any other appliance.

- WHAT TO DO IF YOU SMELL GAS

·

Do not try to light any appliance.

·

Do not touch any electrical switch; do not use any phone in
your building.

·

Clear the room, building or area of all occupants.

·

Immediately call your gas supplier from a neighbor’s phone.
Follow the gas suppliers instructions.

·

If you cannot reach your gas supplier, call the fire
department.

Installation and service must be performed by a qualified installer,
service agency or the gas supplier.

Summary of Contents for GCRH410

Page 1: ...tallation Requirements 2 Electrical Requirements 2 Grounding Requirements 2 Water Supply Requirements 2 Drain Requirements 2 Rough In Dimensions 3 Location Of Your Washer 4 Unpacking 4 Installation 4...

Page 2: ...andpipe use hose P N 134369410 available from an authorized parts distributor PRE INSTALLATION REQUIREMENTS Tools Required for Installation 1 Phillips screwdriver 2 10 mm socket with ratchet 3 Channel...

Page 3: ...3 ROUGH IN DIMENSIONS NOTE For pedestal or undercounter installation reference page 5 Installation With leveling leg lock nuts removed A A...

Page 4: ...the carton 5 Carefully move the washer to within 4 feet 122cm of the final location 6 Remove the following from the back panel of the washer 4 packaging bolts 4 spacers 2 metal P clamps 7 Cover the b...

Page 5: ...leg lock nuts 1 For free standing installation and with the washer in it s final position place a level on top of the washer Adjust the leveling legs so the washer is level front to rear and side to...

Page 6: ...ched to the left hand side panel on the inside of the washer REPLACEMENT PARTS If replacements parts are needed for your washer contact the source where you purchased your washer Destroy the carton an...

Page 7: ...incombe aupropri tairedelalaveusedecontacterun lectricienagr pour remplacer cette prise par une prise trois ouvertures convenablementmise laterre ALIMENTATION EN EAU Lesrobinetsd eauchaudeetd eaufroid...

Page 8: ...riv e d eau C t Arri re po cm po cm po cm po cm po cm po cm po cm po cm po cm po cm Cordon d alimentation Boyau d vacuation Avec niveler des contre crous de jambe enlev s A A NOTE Pour l installation...

Page 9: ...entetoises 2 attaches pressio d gager cordon du service Enlevez les fixations gaunches et droits de mousse Enlevez les 2 Vis et sous le Panneau de Service 7 Couvrez les trous de boulon de prises situ...

Page 10: ...fournis avec cet appareil Mise niveau de la laveuse Le bruit et la vibration excessifs peuvent tre emp ch s en nivelant correctement la laveuse et en serrant les contre crous de mise niveau de jambe...

Page 11: ...uet de cl ture la colonne le tuyau d admission le baquet de blanchisserie etc ainsi le tuyau ne retire pas de la force de l eau 6 Brancher le cordon d alimentation lectrique dans une prise murale mise...

Reviews: