2. Bracket Geared Motor Assembly (Dispenser Models Only)
1) Disassembling Procedure
2) How to check the Hose Ice Maker Tube As.
HOW TO CHECK EACH PART
No
No
1
4
Procedure
Procedure
2
5
And unscrew 4 points.
Unscrew 6 points.
Remove 2 screws.
Pull the Bracket Geared Motor.
Check solenoid Valve and Motor.
Separate 6 pin connector of Geared Motor.
3
6
( Good ): 11.3 Ohm (+-10%)
(10.8 ~ 12.7 Ohm)
(Defective): Change the part.
( Good ): 145 Ohm (+-8%)
(133 ~ 156 Ohm)
(Defective): Change the part.
Checkthe resistance of
2 terminals with a Tester.
Checkthe resistance of
2 terminals with a Tester.
Cube Soloneid Valve
Geared Motor
Parts
How to Check
Remark
28
Summary of Contents for GCW200YAWC
Page 1: ...Pub No DWWR1053E GC 200YAWC GC 200YHWC GC 200NGWC GC 200NHWC...
Page 3: ...2 External Size Features are model dependent All model has same size SPECIFICATIONS 2...
Page 27: ...1 Basic Model 2 Dispenser Model WIRING DIAGRAM 26...