130676

Specification Created 11/08

Listed by 

Underwriters 

Laboratories

ZVB36SN/BN

GE Monogram

® 

36" Telescopic Downdraft Vents

Dimensions and Installation Information (in inches) 

Creative Solutions

Against-the-wall installation 

Move the base cabinet forward, 3" to 5". Filler panels or 

complimentary moldings can be added to the exposed  

cabinet sides.

Island or peninsula installation 

Use an extra-deep countertop. The countertop overhang at the 

front can be adjusted to meet setback to cutout requirements.

Decorative trim 

When the cutout to front edge of the countertop 

requirement is more than 2", add a bullnose trim to the 

front edge of the countertop. The additional trim allows 

the cooktop to be moved forward, providing additional 

countertop depth and interior cabinet space. 

605Dia159

Base Cabinet

Filler Panel

Base Sink

Filler Panel

Maintain Cutout Clearances

to Front Edge as Specified

605Dia160

Cover Panel

Base Sink

End

Panel

Countertop Overhang per Cooktop

Clearances Must be Maintained

605Dia161

DOWNDRAFT 

VENT

1-7/8"

Trim

Add a Bullnose 

Trim or Decorative 

Molding to 

Increase 

Countertop 

Depth and to 

Maintain 

Required 

Clearance From

Front Edge 

Optional Accessories

JXRB67

 Accessory for indoor remote location of the blower/

motor assembly. Use this kit when the blower and motor 

assembly will be located outside of the cabinet, such as 

below the cabinet floor. The assembly will fit between 16" 

floor joists.

JXBC67

 Outdoor cover accessory for remote installation of 

the blower/motor assembly on an outside wall.

Ductwork

Prepare the ductwork to vent to the outdoors. 

•  Plan the shortest and straightest route for venting exhaust 

to the outdoors. 

•  The maximum permissible length for the duct run is 150 feet.

• Use metal ductwork only.

•  The downdraft blower system is designed to use 3-1/4" x 

10" duct. It can be transitioned to 6" round.

•  Install a wall cap or roof cap with damper at the exterior 

opening. Order the wall cap and any transition needed in 

advance.

Summary of Contents for GE Monogram ZVB36BN

Page 1: ...n For accurate planning review the individual dimension drawings for the combined vent and Monogram cooktop installation Before you begin you must 1 Review countertop dimension illustrations to be sure you will have enough flat countertop surface depth 2 Check to be sure that the total countertop depth required including minimum cutout to front edge depth allows enough space for a backsplash 3 Rev...

Page 2: ...anel Base Sink Filler Panel Maintain Cutout Clearances to Front Edge as Specified 605Dia160 Cover Panel Base Sink End Panel Countertop Overhang per Cooktop Clearances Must be Maintained 605Dia161 DOWNDRAFT VENT 1 7 8 Trim Add a Bullnose Trim or Decorative Molding to Increase Countertop Depth and to Maintain Required Clearance From Front Edge Optional Accessories JXRB67 Accessory for indoor remote ...

Page 3: ...ctrical and Gas Locations Plan the placement of the electrical outlet and gas if used carefully Gas or electrical outlets cannot be located on the back wall of the cabinet because they may interfere with the downdraft plenum Install a standard electrical outlet within reach of the vent s two foot long power cord Locate the outlet inside the cabinet on the right side wall If the vent is installed i...

Page 4: ... When You Cook Then Retracts When Not in Use 500 CFM Performance Helps Keep Your Kitchen Free of Fumes and Excess Heat Remote Mounted Control Provides Design Flexibility Variable Speed Blower with Electronic Controls Complements Most Monogram Cooktops Removable Grease Filters Trap Airborne Grease Particles Optional Remote Blower Capabilities Stainless Steel Vent Body Offers a Smooth and Polished A...

Reviews: