background image

Tetra

®

 LED Control Module

(GECLPS3-2)

GE

Lighting Solutions

Installation Guide

imagination at work

24

Volt

Save These Instructions

Use only in the manner intended by the manufacturer.

If you have any questions, contact the manufacturer.

 WARNING/AVERTISSEMENT

RISK OF ELECTRIC SHOCK
• Disconnect power at fuse box or circuit breaker before  

   servicing or installing product.
• Properly ground Tetra

®

 power supply.

RISK OF FIRE
• Use only Tetra

®

 supply wire to make connection from 

   Tetra

®

 power supply to Tetra

®

 LED strip.

• Use only approved wire for input/output connection.

   Minimum size 18 AWG (0.82 mm2)

• Follow all local codes.

RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant

   l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre l’alimentation électrique Tetra

®

.

RISQUES D’INCENDIE
• N’utilisez que le fil d’approvisionnement Tetra

®

 pour faire la connexion entre   

   l’alimentation Tetra

®

 et la bande DEL Tetra

®

.

• N’utilisez que des fils approuvés pour les entrées/sorties de connexion. Taille  

   minimum 18 AWG (0.82 mm2).
• Respectez tous les codes locaux.

 CAUTION/ATTENTION

RISK OF INJURY
• While performing installations described, gloves, safety glasses  

  or goggles should be worn. 

RISQUE DE BLESSURE
• Lors de l’exécution des installations décrites, des gants, des lunettes de    

  sécurité ou des lunettes de protection doivent être portées.

Prepare Electrical Wiring

Electrical Requirements
• Limited to use in dry and damp locations.
• The grounding and bonding of the LED Driver shall be done in   
  accordance with National Electric Code (NEC) Article 600.
• Follow all National Electric Codes (NEC) and local codes.
• These products are only suitable for connection to a circuit    
  from a Class 2 power source. These products have not been    
  evaluated for use when connected to a power source that does  
  not comply with Class 2 voltage and energy limited supplies.

BEFORE YOU BEGIN

Read these instructions completely and carefully.

This device complies with part 15 of the FCC Rules. Operation 

is subject to the following two conditions: (1) This device may 

not cause harmful interference, and (2) this device must 

accept any interference received, including interference that 

may cause undesired operation.
Note:

 This equipment has been tested and found to comply 

with the limits for a Class A digital device, pursuant to part 

15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference when the 

equipment is operated in a commercial environment. This 

equipment generates, uses, and can radiate radio frequency 

energy and, if not installed and used in accordance with the 

instruction manual, may cause harmful interference to radio 

communications. Operation of this equipment in a residential 

area is likely to cause harmful interference in which case the 

user will be required to correct the interference at his own 

expense.

This Class [A] RFLD complies with the Canadian standard 

ICES-003. Ce DEFR de la classe [A] est conforme à la NMB-003 

du Canada. 

LED Control Module Features

• LED Control Module for GECLPS3 and GECLPS4 retrofit.
• UL: Class 2 input.

Summary of Contents for GECLPS3-2

Page 1: ...e in dry and damp locations The grounding and bonding of the LED Driver shall be done in accordance with National Electric Code NEC Article 600 Follow all National Electric Codes NEC and local codes These products are only suitable for connection to a circuit from a Class 2 power source These products have not been evaluated for use when connected to a power source that does not comply with Class ...

Page 2: ...ied personnel in accordance with applicable local state and country electrical codes Make sure the removal of lighting equipment does not compromise the integrity of the sign body i e water intrusion Fill in all holes 0 5 in 13 mm or smaller with the appropriate amount of rated caulk or sealant For holes greater than 0 5 in 13 mm use an aluminum or zinc coated steel patch with rivets and sealant G...

Page 3: ...D per foot Tetra Strip If you change the dipswitch setting and flip 2 switch to the ON position the power supply can support up to 80 ft 24 4m of Tetra Strip The footage guidelines vary based on the type of Tetra Strip being used The charts below provide the footage requirements for each Tetra Strip type CAUTION Avoid setting the dip switch to the ON position with any setting not listed in the cha...

Page 4: ...nections in accordance with local state or country regulations NOTE The grounding and bonding of the power supply and overall sign shall be done in accordance with National Electric Code NEC Article 600 SIGNXXX R071514 GE Lighting Solutions 1 888 MY GE LED www gelighting com 1 8 8 8 6 9 4 3 5 3 3 GE Lighting Solutions LLC is a subsidiary of the General Electric Company Tetra is a trademark of GE L...