Remove Existing Lighting Equipment

Electrical Connections

Turn off power and remove panel from the channel 

letter.

1

Remove the existing GECLPS3. Do not remove existing 

channel letters and wiring.  
NOTE:

 Follow all federal and local regulations when 

disposing of existing LED drivers.

2

Prior to installation, survey the site for information regarding power and accessibility inside and outside the building.  Ensure that the 

branch circuit supplying the existing LED power supply will be within the voltage ratings of the new LED power supply, and have a 

current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes (whichever is less).
If removal of the existing lighting equipment (see Step 2 in this section) eliminates the disconnect switch, as required by applicable local, 

state, or country electrical codes; a new disconnect switch must be installed. If required, the disconnect switch shall be installed by 

qualified personnel, in accordance with applicable  local, state, and country electrical codes.
Make sure the removal of lighting equipment does not compromise the integrity of the sign body (i.e. water intrusion). Fill in all holes 

0.5 in. (13 mm) or smaller with the appropriate amount of rated caulk or sealant. For holes greater than 0.5 in. (13 mm), use an 

aluminum or zinc coated steel patch with rivets and sealant.

=

GECLPS3

GECLPS3-2

GEPS24-100-XX

One GECLPS3-2 and one 24VDC, 100W, Class 2 Tetra 

LED Driver will be required to replace each GECLPS3 or 

up to four GECLPS4 LED drivers.
NOTE:

 Mount the LED driver and LED control module 

within the sign or other enclosure.

If installing multiple LED control modules or LED drivers in 

the same compartment, keep them at least 2” (50.8mm) 

apart end to end and 4” (101.6mm) apart along the sides.
NOTE:

 All drivers except GEPS24-180U must be installed 

in a enclosure or be provided with a GEPSJB60 LED driver 

extended enclosure.

3

4

4”

2”

LED driver

LED driver

LED driver

LED driver

Components

1

2
3

UL certified 22-14 AWG (0.33-2.08 mm

2

) wire connectors or 

22-18 AWG (0.33-0.82 mm

2

)  .

Tetra

®

 24 Volt Power Supply.

Tetra

® 

LED Control Module.

1

2

3

Summary of Contents for GECLPS3-2

Page 1: ...e in dry and damp locations The grounding and bonding of the LED Driver shall be done in accordance with National Electric Code NEC Article 600 Follow all National Electric Codes NEC and local codes These products are only suitable for connection to a circuit from a Class 2 power source These products have not been evaluated for use when connected to a power source that does not comply with Class ...

Page 2: ...ied personnel in accordance with applicable local state and country electrical codes Make sure the removal of lighting equipment does not compromise the integrity of the sign body i e water intrusion Fill in all holes 0 5 in 13 mm or smaller with the appropriate amount of rated caulk or sealant For holes greater than 0 5 in 13 mm use an aluminum or zinc coated steel patch with rivets and sealant G...

Page 3: ...D per foot Tetra Strip If you change the dipswitch setting and flip 2 switch to the ON position the power supply can support up to 80 ft 24 4m of Tetra Strip The footage guidelines vary based on the type of Tetra Strip being used The charts below provide the footage requirements for each Tetra Strip type CAUTION Avoid setting the dip switch to the ON position with any setting not listed in the cha...

Page 4: ...nections in accordance with local state or country regulations NOTE The grounding and bonding of the power supply and overall sign shall be done in accordance with National Electric Code NEC Article 600 SIGNXXX R071514 GE Lighting Solutions 1 888 MY GE LED www gelighting com 1 8 8 8 6 9 4 3 5 3 3 GE Lighting Solutions LLC is a subsidiary of the General Electric Company Tetra is a trademark of GE L...