18
03 Product Introduction
User Manual
V1.0-2023-10-30
The inverter reserves a dry contact controlling port, which supports connecting additional contactors to
enable/disable the loads, such as household loads, heat pumps, etc.
The load control methods are as follows:
•
Time control: set the time to enable/disable the loads, and the loads will be turned on or off
automatically within the setting time period.
• Switch control: when the control mode is ON, the loads will be enabled; when it is OFF, the loads
will be disabled.
•
BACK-UP load control: the inverter has an integrated relay controlling port, which can control
the loads off or on. In off-grid mode, the loads connected to the relay port can be turned off if
the overload at BACK-UP is detected or the battery SOC value is lower than the battery off-grid
protection setting.
For more detailed instructions, please refer to the WE Mate User Manual.
Load Control
Inverter
Loads
Circuit breaker
N
L1
L2
L3
A1
A2
DO+
DO-
WE Mate
User Manual
Model
Label
Description
GEH25-3U-10
F-I-AFPE-1-2/4-2
F: Full coverage
I: Integrated
AFPE
: Detection and interruption capability provided
1: 1 monitored string per input port
2/4:
2/4 input ports per channel(AFD1: 2 , AFD2: 4)
2: 2 monitored channels
GEH29.9-3U-10
GEH30-3U-10