29
05 Installation
User Manual
V1.0-2023-10-30
CAUTION
• Operations such as transportation, turnover, installation and so on must meet the requirements of
the laws and regulations of the country or region where it is located.
•
Move the inverter to the site before installation. Follow the instructions below to avoid personal
injury or equipment damage.
1.
Consider the weight of the equipment before moving it. Assign enough personnel to move the
equipment to avoid personal injury.
2. Wear safety gloves to avoid personal injury.
3.
Keep balance to avoid falling down when moving the equipment.
5�2 Inverter Installation
5�2�2 Installing the Inverter
5�2�1 Moving the Inverter
NOTICE
•
Avoid the water pipes and cables buried in the wall when drilling holes.
• Wear goggles and a dust mask to prevent the dust from being inhaled or contacting eyes when
drilling holes.
•
Make sure the inverter is firmly installed in case of falling down.
• The DC switch lock of appropriate size should be prepared by customers. The diameter of the
lock hole is 5mm. The lock might not be able to install if the size is inappropriate.
Step 1:
Put the plate on the wall horizontally and mark positions for drilling holes.
Step 2:
Drill holes to a depth of 80mm using the hammer drill. The diameter of the drill bit should be
8mm.
Step 3:
Use the expansion bolts to fix the inverter on the wall.
Step 4: (Optional)
Secure the DC switch with the DC switch lock, ensuring that the DC switch is
"OFF" during installation.
Step 5:
Install the inverter on the mounting plate. For models with handles, please lift the inverter
using the handles. For models without handles, please lift the inverter directly.
Step 6:
Tighten the nuts to secure the mounting plate and the inverter.