Reload Button
Short press to change the number in current location, and long press (2s) to move the cursor
to next position. The inverter will store the time if there is no input over 20 seconds, and the
LCD will automatically return to the main menu and the backlight will switch off.
• MPPT (Maximum Power Point Track) function for Shadow:
The default setting for shadow optimizer is disabled.
Please do not enable the function when there is no shadow on panel. Otherwise it could lead
to generating less power.
Short press the button to enter Shadow Optimize menu. When it shows "
Shadow MPPT
OFF
", it means the shadow optimizer is off. Long press the button for 2s to turn on the
function.
• Power limiting function setting
The Operations of the ON/OFF power limiting function (the default is OFF) and the power
limiting settings (the default is 2% rated) are shown below:
Note:
If the power limiting function is ON, the maximum output power of the inverter will be limited
to the value of the power limiting settings.
You need to enter a password before being able to set the power limit. The default password
is "1111".(This function is only available for Australia/New Zealand)
Long press 2S
Long press 2S
Long press 2S
Long press 2S
Set Power Limit
X
XX %
Short press to select
Number 0 or 1
Short press to select
Number 0~9
Short press to select
Number 0~9
Short press
Or
Short press
Short press
Or
Short press
PF Adjust
Pac = 6000W
Shadow MPPT OFF
Pac = 6000W
Power Limit OFF
Pac = 6000W
Power Limit ON
Pac = 6000W
Set Power Limit
XXX %
Shadow MPPT ON
Pac = 6000W
Set Power Limit
X
X
X %
Set Power Limit
XX
X
%
Long press 2S
6. Operation of display under grid-connected mode.
When the input voltage reaches the inverter's start up voltage, the LCD starts to work, the
yellow light will be turned on and the LCD will display "
Waiting
". More information will be
displayed within a few seconds. If the inverter is connected to the grid, "
Checking XXs
" will
be displayed and a countdown will commence from XX seconds (Different countries or
regions have different regulation of time for countdown). When it shows "
Checking 0S
", you
will hear the relay be triggered some times. Then the LCD will display "
Normal
". The instant
power output will be shown at the bottom of the LCD.
5.3 Wi-Fi/LAN Reset & Wi-Fi/LAN Reload
The two functions are only available for Wi-Fi/ LAN model inverters.
W/L Reset will reboot the Wi-Fi/LAN module without erasing the existing settings.
W/L Reload will recover the Wi-Fi/LAN module back to factory settings.
Please configure the Wi-Fi/LAN as 4.4.1 after using the function.
Press the button until the LCD displays "
W/L Reset
", then long press (2S) until the LCD displays
"
W/L Resetting...
". Stop press and wait for the screen to show "W/L Reset OK" or "
W/L Reset
Failed
".
Press the button until the LCD displays "
W/L Reload
", then long press (2S) until the LCD
displays "
W/L Reloading...
". Stop pressing and wait for the screen to show "W/L Reloading OK"
or "
W/L Reloading Failed
".
5.4 Reload of Wi-Fi/LAN Module using Button
Long press the button on the Wi-Fi/LAN module for at least 5 seconds and then release to
restore factory settings when the inverter is powered on.special software. If insterested, please
contact After-Sales. The software installation package are available on the offical website.
Alternatively, please contact after-sales for more information.