All the products are in conformity with the following 

European provision:

ROHS

The products are fulfilled with the requirements in the 
directive 2011/65/EU of the European parliament and of

council on the Restriction of the use of Certain Hazardous

Substances in Electrical and Electronic Equipment (EU 

RoHS Directive)

WEEE

DISPOSAL REQUIREMENTS:

Your air conditioning product is marked with this

symbol.This means that electrical and electronic

products shall not be mixed with unsorted 

household waste. Do not try to dismantle the 

system yourself : the dismantling of the air

EUROPEAN REGULATIONS

CONFORMITY FOR THE MODELS

1

1+2=

kg

R32

2

kg

2=

1=

B

C

D

F

E

kg

A

This product contains fluorinated greenhouse gases covered 

by the Kyoto Protocol. Do not vent into the atmosphere.

Refrigerant type: R32 

GWP=global warming potential

Please fill in with indelible ink,

          and

on the refrigerant charge label supplied with the product.

The filled out label must be adhered in the proximity of the 

 product charging port (e.g. onto the inside of the stop value 

A  contains fluorinated greenhouse gases covered by the 

Kyoto Protocol

B  factory refrigerant charge of the product: see unit name 

plate

C   additional refrigerant amount charged in the field

D   total refrigerant charge

E   outdoor unit

F   refrigerant cylinder and manifold for charging 

IMPORTANT INFORMATION REGA-

RDING THE REFRIGERANT USED

In accordance with the directive 

2012/19/EU

of the European

parliament, herewith we inform the consumer about the dis-

posal requirements of the electrical and electronic products.

conditioning system,treatment of the refrigerant, of oil and of

other part must be done by a qualified installer in 

accordance

with relevant local and national legislation. Air conditioners 

must be treated at a specialized treatment facility for reuse, 

recycling and recovery. By ensuring this product is disposed 

of correctly, you will help to prevent potential negative cons-

equences for the environment and humen health. Please 

contact the installer or local authority for more information. 

Battery must be removed from the remote controller and dis-

posed of separately in accordance with relevant local and 

nationl legislation.

Contains fluorinated greenhouse gases

covered by the Kyoto Protocol

cover).

Voltage:230V

Climate:T1

CAUTION

:

Tighten the flare nut according to the specified method such as with a torque wrench.If the flare nut 

    is too tight, it may crack after prolonged use, causing refrigerant leakage.

Do not install the air conditioner at any place where there is danger of flammable gas leakage.

    In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.

Take adequate steps to prevent the outdoor unit being used as a shelter by small animals.Small animals

    making contact with electrical parts can cause malfunctions, smoke or fire.

Please instruct the customer to keep the area around the unit clean
The temperature of refrigerant circuit will be high, please keep the inter-unit wire away from copper pipes

    that not thermally insulated.

Only qualified personnel can handle, fill, purge and dispose of the refrigerant.

  3  GWP* value=675

2

  tCO2=(1+2) x 3 /1000

Outdoor Unit

GES-NIG25OUT
GES-NIG35OUT

GES-NMG25OUT

GES-NMG35OUT
GES-NMG50OUT

GES-NMG70OUT

GES-NJG25OUT
GES-NJG35OUT
GES-NJG50OUT
GEM-NM40OUT M
GEM-NM50OUT M

Factory charge (kg) CO2 Equivalent (t)

0.65

0.44

0.94

0.63

1.0

0.68

1.2

0.81

0.90
1.2

0.90

0.61

0.81

0.61

0.5

0.5

0.62

0.62

0.34

0.34

0.42

0.42

- 2014/53/EU(RED)

- 2014/517/EU(F-GAS)
- 2009/125/EC(ENERGY)
- 2010/30/EU(ENERGY)

- 2006/1907/EC(REACH)

WIFI

-Wireless maximum transmit power (20dBm)

-Wireless operating frequency range (2400~2483.5MHz)

Summary of Contents for GES-NIG25OUT

Page 1: ...e front grille Loading and Unloading Transporting Management Storage Requirements 3 Installation Instructions 3 Relocation Procedures 7 Maintenance Instructions 7 Scrapping and Recovery 10 Indoor Outd...

Page 2: ...n easily nd it Install the air conditioner in accordance with the instructions in this installation manual Be sure to use only the specified accessories and parts for installation work Install the air...

Page 3: ...lation Air conditioners must be treated at a specialized treatment facility for reuse recycling and recovery By ensuring this product is disposed of correctly you will help to prevent potential negati...

Page 4: ...e white or red white reflective stripes shall be pasted on the sides and tail of the transporting vehicles to remind the vehicles behind of keeping distance 9 The transporting vehicles shall run at a...

Page 5: ...re source and oil heater shall be avoided below the indoor unit 4 The power supply shall be provided with earthing wire and be reliably earthed 5 While punching the wall with an electric drill whether...

Page 6: ...ting solution The pressure shall be maintained for more than 5 minutes and then whether the system pressure is reduced or not shall be observed In case the pressure is reduced leakage can be identifie...

Page 7: ...tallation is firm or not The unit may fall vibrate or make a noise Whether the inspection on air leakage is completed The refrigerating capacity heating capacity may be insufficient Whether the unit i...

Page 8: ...ontainer internal refrigeration pipelines and refrigeration elements the maintenance at the user s site is allowed including the cleaning and dredging of the refrigeration system requiring no disassem...

Page 9: ...Nitrogen cylinders acetylene cylinders and oxygen cylinders shall be placed separately The distance between the gas cylinders above and the working area involved in open fire shall be at least 6m The...

Page 10: ...the refrigeration system shall be earthed The refrigerant charged shall be of the type and volume specified on the nameplate Excessive charging is not allowed After maintenance of the refrigeration sy...

Page 11: ...During the use of refrigerant charging tools cross contamination of different refrigerants shall be avoided The total length including the refrigerant pipelines shall be shortened as much as possible...

Page 12: ...vacuumized before usage and be kept under normal temperature if possible The recovery equipment shall always be under favorable working state and be equipped with operation instructions to facilitate...

Page 13: ...y attaching a vibration proof mat The marks from to in the gure are the parts numbers The distance between the indoor unit and the oor should be more than 2m The models adopt HFC refrigerant R32 more...

Page 14: ...e Heating insulating material Piping hole cover Fixing of outdoor unit Fix the unit to concrete or block with bolts 10mm and nuts rmly and horizontally When tting the unit to wall surface roof or roof...

Page 15: ...WARNING CAUTION N Open the window and well ventilated the room explosion proof fuse 14...

Page 16: ...32 3 fire or explosion will be caused fire or explosion fire or explosion fire or explosion fire or explosion fire explosion 15...

Page 17: ...R32 2 3 R 2 3 R R32 R32 R32 R32 R32 16...

Page 18: ...shock fire or explosion Install a explosion proof breaker for current leakage at the power source to avoid the risk of the electric shock Do not use large capacity fuses steel wire or copper wire Dam...

Page 19: ...R32 R32 R32 R32 R32 R32 R32 R32 R32 18...

Page 20: ...3 R32 R32 R32 R32 R32 R32 R32 19...

Page 21: ...R32 R32 R32 R32 R32 R32 R32 R32 10A HFC 410A 20...

Page 22: ...G50OUT GES NMG70OUT GES NJG25OUT 800 280 550 510 130 313 GES NJG35OUT 800 280 550 510 130 313 GES NJG50OUT GEM NM40OUT M 780 270 540 566 106 5 317 GEM NM50OUT M 810 288 688 583 113 5 319 5 800 280 550...

Page 23: ...tion A is more than 5m oil trap shoud be installed every 5 7 Max Length In case the pipe length B is more thanDm the refrigerant should be charged according to E g m Connection of pipes charge additio...

Page 24: ...23...

Page 25: ...24 R32 R32...

Page 26: ...mm2 4G1 0mm 2 4G1 0mm 2 GES NIG25OUT GES NIG35OUT GES NMG25OUT GES NMG35OUT GES NJG25OUT GES NJG35OUT GES NJG50OUT GES NMG50OUT GES NIG25OUT GES NMG25OUT GES NIG35OUT GES NMG35OUT GES NJG50OUT GES NMG...

Page 27: ...poor 17 16 15 Lack of refrigerant Check if there is leakage in the unit m 26 Model Connecting wiring Power cable 3G2 5 mm 2 4G1 0 mm 2 DOUBLE DOUBLE GEM NM40OUT M GEM NM50OUT M GEM NM40OUT M GEM NM50...

Reviews: