Installation Instructions

7

13

DRYER EXHAUST TO LEFT OR BOTTOM 

CABINET

WARNING -

 PROTECT YOUR 

HANDS AND ARMS FROM SHARP EDGES 

WHEN WORKING INSIDE CABINET.

Detach and remove the bottom, right or left side knockout 

as desired. Remove the screw inside the dryer exhaust duct 

and save. Pull the duct out of the dryer.

REMOVE

SCREW

AND SAVE.

REMOVE

DESIRED

KNOCKOUT

(ONE ONLY).

Through the rear opening, locate the tab in the middle of 

the appliance base. Lift the tab to about 45º using a flat 

blade screwdriver.

BEND TAB

UP 45

o

RIGHT OR

LEFT SIDE

EXHAUST

PORTION "A"

FIXING

HOLE

10

 BATHROOM OR BEDROOM INSTALLATION

• The dryer MUST be vented to the outdoors. See EXHAUST 

INFORMATION section 6.

• The installation must conform with local codes or, in the 

absence of local codes, with the NATIONAL ELECTRICAL 

CODE, ANSI/NFPA NO. 70.

MOBILE OR MANUFACTURED HOME 

INSTALLATION

• Installation must conform to the MANUFACTURED HOME 

CONSTRUCTION  &  SAFETY  STANDARD,  TITLE  24,  PART 

32-80  or,  when  such  standard  is  not  applicable,  with 

AMERICAN  NATIONAL  STANDARD  FOR  MOBILE  HOME, 

ANSI/NFPA NO. 501B.

• The  dryer  MUST  be  vented  to  the  outdoors  with  the 

termination  securely  fastened  to  the  mobile  home 

structure. (See EXHAUST INFORMATION section 6).

• The vent MUST NOT be terminated beneath a mobile or 

manufactured home.

• The vent duct material MUST BE METAL.

• KIT  14-D346-33  MUST  be  used  to  attach  the  dryer 

securely to the structure.

• The  vent  MUST  NOT  be  connected  to  any  other  duct, 

vent, or chimney.

• Do not use sheet metal screws or other fastening devices 

which extend into the interior of the exhaust vent.

• Provide an opening with a free area of at least 25 sq. in. 

for introduction of outside air into the dryer room.

11

TAB LOCATION

ADDING NEW DUCT

Detach  and  remove  the  bottom  or  left  side  knockout  as 

desired. Remove the screw inside the dryer exhaust duct 

and save. Pull the duct out of the dryer. Protect sharp edges 

around the knockout and exhaust opening with the tape.

Cut the duct as shown and keep portion A.

13 1/2"

A

B

FIXING HOLE

(13 1/4” for bottom venting)

Reconnect the cut portion (A) of the duct to the blower 

housing. Make sure that the fixing hole is aligned with the 

tab in the base. Use the screw saved previously to secure 

the duct in place through the tab on the appliance base.

12

• Dryers installed in residential garages must be elevated

18 inches (46cm) above the floor.

Summary of Contents for GFDS350GLWW

Page 1: ...sit our Web site at www GEAppliances com US BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for local inspector s use IMPORTANT Observe all governing codes and ordinances Note to Installer Be sure to leave these instructions with the customer Note to Customer Keep these instructions with your Use and Care Book for future reference Before the old ...

Page 2: ...EL GAS CODE ANSI Z223 This gas dryer is equipped with a Valve Burner Assem bly for use only with natural gas Using conversion kit WE25X0217 your local service organization can convert this dryer for use with propane LP gas ALL CONVER SIONS MUST BE MADE BY PROPERLY TRAINED AND QUALI FIED PERSONNEL AND IN ACCORDANCE WITH LOCAL CODES AND ORDINANCE REQUIREMENTS The dryer must be disconnected from the ...

Page 3: ...ealant CAUTION Use adaptors as shown Connector nuts must not be connected directly to pipe threads APPLY PIPE COMPOUND TO THE ADAPTER AND DRYER GAS INLET Tighten the flexible gas line using two adjustable wrenches APPLY PIPE COMPOUND TO ALL MALE THREADS Tighten all connections using two adjustable wrenches Do not overtorque gas connections Check all connections for leaks with soapy solution or equ...

Page 4: ...LLOWABLE duct length and number of bends of the exhaust system depends upon the type of duct number of turns the type of exhaust hood wall cap and all conditions noted below The maximum duct length for rigid metal duct is shown in the table below EXHAUST LENGTH 4 DIA 4 4 DIA Exhaust Hood Types No of 90º Elbows Rigid Metal 90 Feet 60 Feet 45 Feet 35 Feet 25 Feet 0 1 2 3 4 RECCOMMENDED MAX LENGTH 5 ...

Page 5: ...azard Do not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard Never install a screen in or over the exhaust duct This will cause lint to accumulate creating a potential fire hazard Do not assemble ductwork with any fasteners that extend into the duct These fasteners can accumulate lint creating a potential fire hazard Do n...

Page 6: ...K Stand the dryer upright near the final location and adjust the 4 leveling legs at the corners to ensure that the dryer is level from side to side and front to rear For many applications installing elbows at both the dryer and the wall is highly recommended see illustrations below Elbows allow the dryer to sit close to the wall without kinking and or crushing the transition duct maximizing drying...

Page 7: ...MUST be vented to the outdoors with the termination securely fastened to the mobile home structure See EXHAUST INFORMATION section 6 The vent MUST NOT be terminated beneath a mobile or manufactured home The vent duct material MUST BE METAL KIT 14 D346 33 MUST be used to attach the dryer securely to the structure The vent MUST NOT be connected to any other duct vent or chimney Do not use sheet meta...

Page 8: ...elbow as shown above DUCT TAPE CAUTION Use 4 rigid metal ducting only inside the dryer Internal duct joints must be secured with tape otherwise they may sepa rate and cause a safety hazard ADDING COVER PLATE TO REAR OF CABINET Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with a plate Kit WE1M454 available from your local service provider Place dryer in ...

Page 9: ... Siga todos los códigos y ordenanzas vigentes Nota al instalador Asegúrese de dejar estas instrucciones con el consumidor Nota al consumidor Mantenga estas instrucciones con el Manual de uso y cuidados para referencia futura Antes de que la secadora antigua sea retirada del servicio o elimi nada quítele la puerta La información sobre reparaciones y el diagrama del cableado se en cuentran en la con...

Page 10: ...anzas locales o si no las hubiera con el CÓDIGO NACIONAL DE GAS ANSI Z223 Esta secadora a gas está equipada con un montaje de válvula y quemador para utilizar sólo con gas natural Mediante el kit de conversión WE25X0217 la organización de atención local puede convertir esta secadora para su uso con gas propano LP TODAS LAS CONVERSIONES DEBEN LLEVARLAS A CABO PERSONAL CAPACITADO Y CALIFICADO EN CUM...

Page 11: ...exión no deben conectarse directa mente en las roscas de la tubería APLIQUE COMPUESTO PARA TUBERÍA AL ADAPTADOR Y A LA ENTRADA DE GAS DE LA SECADORA Ajuste la tubería flexible de gas utilizando dos llaves ajustables APLIQUE COMPUESTO PARA TUBERÍA EN TODAS LAS ROSCAS MACHO Ajuste todas las conexiones mediante dos llaves ajustables No ajuste de más las conexiones de gas Controle todas las conexiones...

Page 12: ...ad de codos del sistema de salida dependen del tipo de conducto la cantidad de curvas la clase de campana de salida cubierta de pared y todas las condiciones indicadas a continuación La longitud máxima del conducto para conductos rígidos de metal se indica en la siguiente tabla 4 DIA 4 4 DIA 90 Feet 60 Feet 45 Feet 35 Feet 25 Feet 0 1 2 3 4 LONGITUD DE SALIDA LONGITUD MÁXIMA RECOMENDADA Tipos de c...

Page 13: ... de una longitud mayor a la especificada en la tabla de longitud de salida Los conductos más largos acumulan pelusa lo que genera un riesgo potencial de incendio Nunca instale un filtro dentro o sobre el conducto de salida Esto provocará la acumulación de pelusas lo que genera un riesgo potencial de incendio No arme la red de conductos con sujeciones que se extiendan dentro del conducto Estas suje...

Page 14: ...LAR FRENTE A PARTE TRASERA Stand the dryer upright near the final location and adjust the 4 leveling legs at the corners to ensure that the dryer is level from side to side and front to rear Para muchas aplicaciones se recomienda enfáticamente la instalacióndecodosenlasecadorayenlapared verilustraciones de abajo Los codos permiten que la secadora se ubique cerca de la pared sin torcer o aplastar e...

Page 15: ...norma no sea aplicable con la NORMA NACIONAL ESTADOUNIDENSE PARA CASAS MÓVILES ANSI NFPA Nº 501B La secadora DEBE tener ventilación al exterior con la terminación bien sujeta a la estructura de la casa móvil Ver la INFORMACIÓN SOBRE SALIDA sección 6 La ventilación NO DEBE terminar debajo de una casa móvil o prefabricada El material del conducto de ventilación DEBE SER METAL DEBEutilizarseelKIT14 D...

Page 16: ...A PRECAUCIÓN Utilice un conducto de metal rígido de 4 sólo dentro de la secadora Las juntas del con ducto interno deben sujetarse con cinta caso contrario pueden separarse y provocar un riesgo de seguridad CÓMO AGREGAR LA PLACA DE CUBIERTA A LA PARTE TRASERA DEL GABINETE Conecte los codos y conductos de metal estándar para completar el sistema de salida Cubra la abertura trasera con la placa Kit W...