Riser
Location:
See Riser Location on page 34.
The riser is an integrated part of the washing
machine and cannot be permanently removed. The
purpose of the riser is to add an additional 7 inches
of height to the washer.
Riser Removal
1. Disconnect power and water supply to unit.
Move washer to an area that allows room to
access the front and back side of the washer.
2. Remove control panel. (See
Control Panel
Removal
)
3. Remove front panel. (See
Front Panel Removal
)
4. Remove rear panel. (See
Rear Panel Removal
)
5. Lay unit on its side and remove the four riser
mounting bolts.
9/16 Hex
9/16 Hex
9/16 Hex
9/16 Hex
Front Tub
Front Tub
Overnight Dry Filter
O-RIng Seal
Location:
See Front Tub Location on page 37.
The front tub is mated to the rear tub with sixteen
3/8” hex head screws. An O-ring seal shown above
(not part of the front tub) is placed between the two
tubs to prevent water leaks.
On models that have the overnight dry feature, an
air
fi
lter is housed inside the overnight dry hose
collar as show above.
Front Tub Removal
1. Disconnect power to the unit.
2. Remove the control panel. (See
Control Panel
)
3. Remove the top panel. (See
Top Panel
)