10.1.10
Reconditioning the Holder
• Attach lifting tackle to the upper flange of the chamber insulator.
• Loosen and remove two screws (17) on the lower flange of the
chamber insulator (1).
• Lift up the chamber insulator.
• Replace the two guide strips (18). The guide strips are located in
dovetail grooves. It is therefore necessary to overcome
mechanical resistance when replacing it.
• Clean the sealing and flange surfaces of the holder (16) and
grease them per lubrication specification L3.
• Replace the formed gasket (19).
• Lubricate two screws (17) per L1.
• Replace the chamber insulator and fasten it with two screws (17).
Tighten to a torque of 17Nm.
Fill the counterbores in the holder completely with grease per L3.
1
Chamber insulator
1x
16
Holder
1x
17
Socket head cap screw, M8x20 A-70
2x
18
Guide strip, 3x5x146
2x
19
Formed gasket 271
1x
1
19
18
16
L1
18
L3
17
17
BA
-P
-PS
-10
Summary of Contents for GL 311 F3/4031 P/VE
Page 2: ......
Page 10: ...INTRODUCTION 10 146 OI 250 EN REV7 REV6...
Page 12: ...SAFETY 12 146 OI 250 EN REV7 REV3...
Page 48: ...INSTALLATION 48 146 OI 250 EN REV7 REV7...
Page 80: ...INSPECTION AND MAINTENANCE 80 146 OI 250 EN REV7 REV3...
Page 102: ...RECONDITIONING 102 146 OI 250 EN REV7 REV7...
Page 104: ...END OF LIFE MANAGEMENT 104 146 OI 250 EN REV7 REV2a...
Page 114: ...SPECIAL EQUIPMENT OPTIONAL 114 146 OI 250 EN REV7 REV0...
Page 128: ...REPLACEMENT PARTS AND ACCESSORIES 128 146 OI 250 EN REV7 REV6...
Page 130: ...HANDLING USED SULFUR HEXAFLUORIDE 130 146 OI 250 EN REV7 REV2...