– 9 –
:LQGLQJV &RLOV5HVLVWDQFH9DOXHV*DV
Main Drum Motor
Start
Run
Gas Valve
Main
Booster
Safety
,JQLWHU
-
#
Timer Motor
-
3384 - 3816
,QOHW
Outlet
Biased Thermostats
-
9k
Thermostat
Temperature
°
F
Temperature
°
C
Open
Close
Open
Close
Drum Outlet
130 +/- 5
120 +/- 6
55 +/- 3
49 +/- 3
Control Inlet
210 +/- 5
180 +/- 6
99 +/- 3
82 +/- 3
Safety 27" Models
280 +/- 5 240 +/- 12 138 +/- 4
116 +/- 7
Safety 24" Models
300 +/- 5 260 +/- 12 184 +/- 4
127 +/- 7
+LJK/LPLW
315 +/- 8 250 +/- 15 157 +/- 6
121 +/- 9
Terminal
Wire Color
C
Pink
U
Brown/Yellow
Y
Yellow
X
Yellow
A
Orange
T
Tan
S
Blue
B
Red
F
Not Used
Gas Dryer