Installation Instructions
EXHAUSTING THE DRYER (cont.)
Using exhaust longer than specified length will:
• Increase the drying times and the energy cost.
• Reduce the dryer life.
• Accumulate lint, creating a potential fire hazard.
The correct exhaust installation is YOUR
RESPONSIBILITY.
Problems due to incorrect installation are not
covered by the warranty.
The MAXIMUM ALLOWABLE length of the exhaust
system depends upon the type of duct, number of turns,
the type of exhaust hood (wall cap) and all conditions
noted on the chart.
• Internal elbows added for side or bottom vent
conversions must be included in the total elbow count.
• Any elbow greater than 45° should be treated as a 90°
elbow; one elbow of 45° or less may be ignored.
• Two 45° elbows will be treated like one 90° elbow. For
the side exhaust installations, add one 90° elbow to the
chart.
• For every additional 90° elbow, reduce the allowable
vent system length by 10 feet.
• When calculating the total vent system length, you
must add all the straight portions and elbows of the
system (including the transition duct).
EXHAUST LENGTH
•
DO NOT
bend
or collapse
ducting. Use
elbows if turns
are necessary.
•
DO NOT
use
excessive
exhaust
length. Cut
duct as short
as possible.
•
DO NOT
crush duct
against the
wall.
•
DO NOT
set
appliance
on duct.
•
DO
cut duct as short as
possible and install straight
into wall.
•
DO
use elbows when turns are
necessary.
EXHAUST
LENGTH
27”
NORMAL
VENT
MODELS
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
Use only for short run
installations
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
No. of 90° Elbows
Rigid Metal
Rigid Metal
0
56 Feet
42 Feet
1
48 Feet
34 Feet
2
40 Feet
26 Feet
3
32 Feet
18 Feet
EXHAUST
LENGTH
24”
NORMAL
VENT
MODELS
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
Use only for short run
installations
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
No. of 90° Elbows
Rigid Metal
Rigid Metal
0
43 Feet
36 Feet
1
33 Feet
26 Feet
2
24 Feet
16 Feet
EXHAUST
LENGTH
27” LONG
VENT
MODELS
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
Use only for short run
installations
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
No. of 90° Elbows
Rigid Metal
Rigid Metal
0
200 Feet
175 Feet
1
185 Feet
165 Feet
2
175 Feet
155 Feet
3
165 Feet
145 Feet
4
155 Feet
135 Feet
5
145 Feet
125 Feet
Elbows
Summary of Contents for GUD24GSSMWW
Page 18: ...18 Notes ...
Page 19: ...19 Notes ...
Page 20: ...20 Printed in Mexico ...
Page 38: ...Notes 18 ...
Page 39: ...19 Notes ...
Page 40: ...20 Imprimé au Mexique ...
Page 58: ...Notas 18 ...
Page 59: ...19 Notas ...
Page 60: ...20 ...