Before you call for service…
22
Problem
Possible Causes
What To Do
Salty tasting or
Unit not sanitized
•
Complete the
Sanitization Procedures
on page 12.
brown/yellow colored
•
At completion of recharge cycle (approx. 2 hrs), run water
water after installation
from faucets to purge the salty water.
Low water pressure
Check pressure.
•
Drain height 8
′
or less, pressure should be minimum of 20 psi.
•
Drain height above 8
′
, pressure should be minimum of 50 psi.
Restricted drain hose
•
Clean and reconnect hose.
•
Check for kinks in drain line.
Brown/yellow
Unit was idle for a period of time
•
Complete the
Sanitization Procedures
on page 12.
colored water
Resin beads showing
Cracked distributor
•
Call for service.
up in drinking water
and sink
Sounds you might hear
Running water from the unit
•
This is normal.
into a drain during recharge
Water has air bubbles
Air in system after installation
•
Will go away after it runs for a while.
and is cloudy
Error Code on control
Wiring may have worked loose
•
See page 16 for details.
in the control
•
Unplug transformer.
•
Remove control cover, release clips on side.
•
Check for loose/incorrect wiring connections to electronic
board or switch. Reconnect as required.
•
Reassemble control cover.
•
Plug in Transformer.
•
Wait six minutes for Error Code to reappear.
•
If Error Code reappears, call for service.
Troubleshooting Tips
Summary of Contents for GXSF30H
Page 24: ...24 Parts list ...
Page 52: ...52 Notas ...
Page 53: ...53 Notas ge com ...
Page 55: ...55 ge com ...