4310-0008: 220VAC Power Supply 

Power Supply Input 

Voltage:

  220 Volt AC 

Tolerance:

  ±10% 

Frequency:

  50 Hz

 

Power Supply Output 

Voltage:

  12 Volt DC 

Current:

  110mA 

Power:

  1.3 Watts 

Connector:

  2.1mm female barrel.  Center Positive

 

1.3 

P

RO

B

RIDGE 

G

ATEWAY 

P

RODUCT 

D

IAGRAM

 

 

4

8

7

6

5

3

2

1

6

5

1

2

3

4

7

8

6

5

1

2

3

4

7

8

6

5

1

2

3

4

7

8

12V DC

RS-232

PORT 2

RS

-4

85

PO

R

T 0

RS

-2

32

 / R

S-4

85

PO

R

T 1

RS-485 SEL

RS-232 SEL

TERM 1

BIAS 1 -

BIAS 1 +

TERM 0

BIAS 0 -

BIAS 0 +

PO

R

T 0

PO

R

T 1

8

7

6

5

4

3

2

1

O

F

F

O

N

8

7

6

5

4

3

2

1

O

F

F

O

N

8

7

6

5

4

3

2

1

O

F

F

O

N

8

7

6

5

4

3

2

1

O

F

F

O

N

SW

1

SW

2

SW

3

SW

4

Ka

lat

el P

ro B

rid

ge

e

SW1
Dipswitch 1-8

Port 2
RS232

Power Supply
Connector 12VDC

Port 1
RS232/RS485
Selectable 

Port 0
RS485 
Network Bus

SW2
Dipswitch 1-8

SW3
Dipswitch 1-8

SW4
Dipswitch 1-8

 

 

Note:

 Port 0 and Port 1 have looping RJ45 connectors. 

 

1.3.1 

D

IPSWITCH 

P

OSITION 

L

EGEND

 

 

 

Summary of Contents for Interlogix 0150-0265A

Page 1: ...S 485 PORT 0 RS 232 RS 485 PORT 1 RS 485 SEL RS 232 SEL TERM 1 BIAS 1 BIAS 1 TERM 0 BIAS 0 BIAS 0 PORT 0 PORT 1 8 7 6 5 4 3 2 1 O F F O N 8 7 6 5 4 3 2 1 O F F O N 8 7 6 5 4 3 2 1 O F F O N 8 7 6 5 4 3 2 1 O F F O N SW1 SW2 SW3 SW4 Kalatel Pro Bridge e ...

Page 2: ...pplication of any of the contents of this document For the latest product specifications visit GE Interlogix Kalatel division online at www kalatel com or contact your Kalatel sales representative For technical support before and after installation call 800 469 1676 Technical support is available 24 hours a day 7 days a week Call Tech Support 800 469 1676 6 A M 5 P M PST Monday through Friday Tech...

Page 3: ...AMMING MODE 8 3 OPERATING MODE 9 4 OPERATION 10 4 1 MESSAGE TRANSLATION FROM LEGACY IMPAC RS485 NETWORK TO THE KALATEL RS485 NETWORK 10 4 1 1 Addressing 10 4 1 2 Preset 10 4 1 3 Movement Speed 11 4 2 MESSAGE TRANSLATION FROM KALATEL RS485 NETWORK TO LEGACY IMPAC RS485 NETWORK 13 5 CABLE SPECIFICATIONS 14 5 1 PROBRIDGE TO DVMRE TRIPLEX CABLE 14 5 2 PROBRIDGE TO PC LAPTOP CABLE 14 5 3 PROBRIDGE TO I...

Page 4: ...ing maintaining and troubleshooting this product refer to this document and any other documentation provided If you still have questions contact Kalatel Technical Support GE Interlogix Kalatel division Call 800 469 1676 Fax 541 752 9096 Note You should be at the equipment ready with details before calling Technical Support Conventions Used in this Manual Boldface or button icons highlight command ...

Page 5: ...r 983 In the Operating mode the ProBridge Gateway will translate messages to ensure that telemetry messages originating from Mux DVMRe products will correctly address the intended dome 1 1 PROBRIDGE GATEWAY COMPONENTS The ProBridge Gateway product includes 1 CBR PB3 GW ProBridge unit 1 P N 4310 0034B RJ45 to RJ45 cable Connects the ProBridge Gateway RS485 Port 0 to the DVMRe Triplex RS485 port Thi...

Page 6: ...laced by custom made cables to address distances between components ensure the cable is manufactured to ANSI standards for RS 232 communication RS485 Limitations If multiple PB3 units are connected to a single DVMRe unit the distance between the first and last ProBridge unit is limited to 3 000 feet RS 485 communications 1 2 POWER The ProBridge is furnished with a power supply 110 or 240 VAC Do no...

Page 7: ... 4 7 8 6 5 1 2 3 4 7 8 12V DC RS 232 PORT 2 RS 485 PORT 0 RS 232 RS 485 PORT 1 RS 485 SEL RS 232 SEL TERM 1 BIAS 1 BIAS 1 TERM 0 BIAS 0 BIAS 0 PORT 0 PORT 1 8 7 6 5 4 3 2 1 O F F O N 8 7 6 5 4 3 2 1 O F F O N 8 7 6 5 4 3 2 1 O F F O N 8 7 6 5 4 3 2 1 O F F O N SW1 SW2 SW3 SW4 Kalatel Pro Bridge e SW1 Dipswitch 1 8 Port 2 RS232 Power Supply Connector 12VDC Port 1 RS232 RS485 Selectable Port 0 RS485...

Page 8: ...s Connect to tab Configure button o Set local echo on File Properties Settings tab ASCII Setup button Cycle power on the ProBridge Gateway box and follow the instructions in HyperTerminal Connection Diagram for programming mode is shown below 12V DC RS 232 PORT 2 RS 485 PORT 0 RS 232 RS 485 PORT 1 RS 485 SEL RS 232 SEL TERM 1 BIAS 1 BIAS 1 TERM 0 BIAS 0 BIAS 0 PORT 0 PORT 1 8 7 6 5 4 3 2 1 O F F O...

Page 9: ...erating mode is shown below 12V DC RS 232 PORT 2 RS 485 PORT 0 RS 232 RS 485 PORT 1 RS 485 SEL RS 232 SEL TERM 1 BIAS 1 BIAS 1 TERM 0 BIAS 0 BIAS 0 PORT 0 PORT 1 8 7 6 5 4 3 2 1 O F F O N 8 7 6 5 4 3 2 1 O F F O N 8 7 6 5 4 3 2 1 O F F O N 8 7 6 5 4 3 2 1 O F F O N SW1 SW2 SW3 SW4 Kalatel Pro Bridge e DVMRe Triplex ProBridge Gateway RJ45 TCP IP RS485 RS485 RS485 RS422 4310 0034B Cable 4310 0032A C...

Page 10: ...t On the drop down menu select the preset number from preset 1 to16 Click Go to to recall that preset Presets can also be generated on Muxes that have advanced alarm handling capability The DVMRe will receive these preset messages via TCP IP and convert them to RS485 They will appear at port 0 in the following format Message format Synchronization 0xFF Length 0x07 Message type 1 0x09 Message type ...

Page 11: ...er Motor Message format Synchronization 0xFF Length 0x07 Message type 1 0x09 Message type 2 0x05 Destination Impac Mux DVMRe Source Impac Mux DVMRe Camera number Camera connected to Mux DVMRe 00 0F Motor command Impac motor command Checksum 2 s complement Variable Speed Message format Synchronization 0xFF Length 0x0B Message type 1 0x09 Message type 2 0x0C Destination Impac Mux DVMRe Source Impac ...

Page 12: ... converts these messages to 312 messages as follows Port 0 Example with Iris Close Start on WaveReader Motor Message format Synchronization 0xFF Length 0x07 Message type 1 0x09 Message type 2 0x05 Destination Impac Mux DVMRe Source Impac Mux DVMRe Camera number Camera connected to Mux DVMRe 00 0F Motor command Iris Close Start Impac motor command Checksum 2 s complement Port 1 Iris Focus message a...

Page 13: ...SAGE TRANSLATION FROM KALATEL RS485 NETWORK TO LEGACY IMPAC RS485 NETWORK All messages are passed through unchanged transparent with the exception of Kalatel Menu Mode messages which are blocked Message types 0x08 0x09 0x10 0x11 0x12 0x13 and 0x14 are passed through ...

Page 14: ...ange White Pin 8 Brown Pin 7 Brown White Pin 6 Green Pin 5 Blue White Pin 4 Blue Pin 3 Green White Pin 2 Orange Pin 1 Orange White RJ 45 Connector RJ 45 Connector 5 2 PROBRIDGE TO PC LAPTOP CABLE Part Number 4310 0047B Communication Type RS232 Connector Type RJ 45 DB9F Cable Required 6 Foot RJ 45 to DB9F RS232 Cable Supplied Connects ProBridge to the serial port of a PC or Laptop computer NOTE Thi...

Page 15: ...X Part Number 4310 0032A Communication Type RS485 Connector Type RJ45 Flying Leads Cable Required RS 485 Flying Leads Cable Interconnects ProBridge with KTD 405 and Dome Cameras Pin 8 Pin 7 Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1 RJ 45 Flying Leads Black Red Connector RJ45 Connector Flying Leads ...

Page 16: ...ply and manual Color Black Environmental Temperature 0 to 40 C operating Relative Humidity 90 non condensing Electrical AC Power External AC power supply included Voltage Range 110 to 240 VAC 10 Current 200 mA DC Power DC jack positive center Power Supply Voltage 12 VDC Current 110 mA Power 1 5 W Note All specifications are subject to change without notice Kalatel believes that all specifications ...

Page 17: ... parts labor and shipping Labor will be billed in half hour increments Note Customers requesting an estimate prior to repair will be notified by phone If they cannot be reached they will be notified by fax If we are unable to reach the contact person for repair authorization after one phone attempt and two fax attempts the equipment will be returned without being repaired We will hold equipment no...

Page 18: ......

Reviews: