Lennox heat pump
V or VR or R
RH power for heat.
M or Y
Y cool control.
Y or W or W2
W2 2nd-stage heat.
F or G
G fan control.
R or O
O
X or X2 or C
C
Trane products (American Standard)
B
C 24 VAC power (to power thermostat).
W or W1
W2 2nd-stage heat.
X2
Emergency heat (do not connect, tape off).
Two-wire zoned hot water
R RH
W W
Three-wire motor driven valves
R or 5
RH (power)
W or 4
W (heat on)
Y or G or 6 (3rd wire)
A (heat off)
Three-wire solenoid valves
R RH
(power)
W
A (heat on)
Y or G (3rd wire)
W (heat off)
Specifications
Voltage
24 VAC (supplied via the C wire)
Batteries
Three AA alkaline batteries ( Duracell, Energizer). Do not use
rechargeable batteries.
Dimensions (W x H x D)
5.5 x 3.5 x 1.5 in. (140 x 89 x 38 mm)
Operating environment
Temperature
Relative humidity
Indoor use only
32 to 104
°
F (0 to 40
°
C)
10 to 90% noncondensing
P/N 1069510 • REV A • ISS 09NOV10