Electrical Power Supply Requirements
Recommended Electrical Outlet Locations
Provide Proper Electrical Supply
These ranges must be supplied with 208/240 volt,
60 Hz., and connected to an individual, properly
grounded branch circuit protected by a circuit
breaker or time-delay fuse (40 amp). The
receptacle must be NEMA 14-50R to accept
the 4-prong plug supplied with the range.
If the electrical service provided does not meet
the above specifications, it is recommended that
a licensed electrician install an approved outlet.
■
Locate the electric supply as illustrated.
Recommended acceptable
electrical outlet area. Orient
the electrical receptacle so the
length is parallel to the floor.
7
1
⁄
2
”
8”
4”
30”
3”
Product is shipped with 4-prong
plug. Recommended outlet is a
NEMA 14-50R receptacle.
2
1
⁄
4
”
Wall Mounted
NOTE:
Make electrical connections
on the right side of the cutout opening.