32
INSTALLATION INSTRUCTIONS
(continued)
STEP 4
3 WIRE POWER CORD INSTALLATION
Remove the 3 wire terminal screws from
the connector block. Insert screws through
each power cord terminal ring and into the
connector block until the screws engage the
nuts. Be certain that the center wire is connected
to the center screw of the connector block.
Tighten screws securely. Do NOT remove
ground strap connection.
WARNING: THE NEUTRAL OR GROUND
WIRE OF THE POWER CORD MUST BE
CONNECTED TO THE NEUTRAL
TERMINAL LOCATED IN THE CENTER OF
THE CONNECTOR BLOCK. THE POWER
LEADS MUST BE CONNECTED TO THE
OUTSIDE (BRASS COLORED) TERMINALS.
NEUTRAL
TERMINAL
GROUND
STRAP
CONNECTOR
BLOCK
POWER CORD
STEP 5
4 WIRE POWER CORD INSTALLATION
A. Remove the 3 screws from the connector
block.
B. Remove the grounding screw and strap from
the connector block middle location and the
screw connection to the frame of the range.
C. Insert screws through each power cord
terminal ring and into connector block until
screw engages nut. Be certain that the center
wire is connected to the center screw of the
connector block. Tighten screws securely.
D. Attach ground wire to the frame of the range.
WARNING: THE NEUTRAL WIRE OF
SUPPLY CIRCUIT IS CONNECTED TO
THE NEUTRAL TERMINAL LOCATED
IN THE CENTER OF THE CONNECTOR
BLOCK. THE POWER LEADS MUST
BE CONNECTED TO THE OUTSIDE
(BRASS COLORED) TERMINALS. THE
4TH GROUNDING LEAD MUST BE
CONNECTED TO THE FRAME OF THE
RANGE WITH THE GROUNDING SCREW.
BEFORE
NEUTRAL
TERMINAL
GROUNDING STRAP
(GROUNDING TO RANGE)
AFTER
NEUTRAL
TERMINAL
GROUNDING
TO RANGE