Installation Instructions
Installing the Anti-Tip Bracket
C
a.
For concrete installation you will need two
1/4"x 1-1/2" lag screws, and two sleeve
anchors.
b.
Locate the center of the four holes identified
in Fig. 1 as Floor-Concrete and Wall. Drill
the recommended size holes in each.
c.
Install the sleeve anchors into the predrilled
concrete holes and install the lag and wall
screws through the Anti-Tip bracket. Make
sure the screws are securely tightened.
a.
Locate the centers of the four holes identified
in Fig. 1 as Floor-Wood and Wall.
b.
Drill a 1/8" pilot hole through the pre-marked
areas. Note the angle of the wall screw in
Fig. 2.
c.
Mount the Anti-Tip bracket with the four
screws provided.
Locating The Bracket
a.
Decide whether the bracket will be
installed on the right or left side of range
location.
b.
If the bracket side of the range has an
adjacent cabinet, place the bracket
against the back wall and cabinet as
shown in Fig. 1. If there is a countertop
overhang, offset the bracket by the
amount of overhang. If there is no
adjacent cabinet, place the bracket to the
outside edge of the range side panel and
back wall.
Fig. 1
Installing The Bracket in Wood
or Concrete
C1
INSTALLATION–WOOD CONSTRUCTION
INSTALLATION–CONCRETE CONSTRUCTION
C2
Fig. 2
The anti-tip bracket, provided with your literature
and broiler pan, must be properly installed to
prevent the range from tipping. Please refer to
the instructions provided with your anti-tip
bracket.
Adjacent Cabinet
Or Final Location
Of Range Side Panel
Wall
Floor-Wood
Bracket
Side
Rear
Leveling
Leg
Floor-Concrete
Attachment To Wall
Bracket
Wall
Plate
Screw Must
Enter Wood
Or Metal