❑
CONNECT THE
TO
(continued)
1. Install a manual gas line shut-off valve in the
gas line in an easily accessed location outside of
the range. Make sure everyone operating the
range knows where and how to shut off the gas
supply to the range.
2. Install male 1/2” flare union adapter to the
1/2” NPT internal thread elbow at inlet of
regulator. On models equipped
standard
burners, install the male pipe
thread end of the 1/2” flare union adapter to the
1/2”
internal thread at inlet of pressure
regulator. Use a backup wrench on the regulator
fitting to avoid damage.
installing the range from the front,
remove the 90° elbow for easier installation.
3. Install male 1/2” or 3/4” flare union adapter
to the NPT internal thread of the manual shut-
off valve, taking care to back-up the shut-off
valve to keep it from turning.
Connect flexible metal appliance connector
to the adapter on the range. Position range
to permit connection at the shut-off valve.
5.
all connections have been made, make
sure all range controls are in the off position and
turn on the main gas supply valve. Use a liquid
leak detector at all joints and connections to
check for leaks in the system.
DO NOT USE A
TO
CHECK FOR GAS
using test pressures greater than 1/2 psig
to pressure test the gas supply system of the
residence, disconnect the range and individual
shut-off valve from the gas supply piping.
using test pressures of 1/2 psig or less to test the
gas supply system, simply isolate the range from
the gas supply system by closing the individual
shut-off valve.
❑
CONNECTIONS
(on some
Electrical Requirement
60 Hertz, properly grounded branch
circuit protected by a 15-amp or
circuit
breaker or time delay fuse.
Extension Cord Cautions
Because of potential safety
associated
with certain conditions, we strongly recommend
against the use of an extension cord. However,
if you still elect to use an extension cord, it is
absolutely necessary that it be a
3-wire grounding-type appliance extension cord
and that the current carrying rating of the cord
in amperes be equivalent to, or greater than,
the branch circuit rating.
Grounding
read
FOR PERSONAL SAFETY, THIS
MUST BE
GROUNDED.
The power cord of this appliance is equipped
with a three-prong
plug which
mates with a standard three-prong grounding
wall receptacle
PREFERRED ,
METHOD
to
minimize the
@Q
possibility of
electric shock
hazard from
this appliance.
The customer
Ensure proper
should have the
ground exists
wall receptacle
before use
and circuit
checked by a
qualified electrician to make sure the receptacle
is properly grounded.
a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with
a properly grounded
wall receptacle.
DO
NOT, UNDER
CIRCUMSTANCES,
CUT OR
THE THIRD (GROUND)
PRONG FROM THE
CORD.
(continued next page)
39
Summary of Contents for JG5P34
Page 52: ...NOTES 52 ...
Page 53: ...NOTES 53 ...