GENERAL
.
See
Dimensions and Clearances in this section
for all rough-in and spacing dimensions. These
dimensions must be met for safe use of your range.
The location of the electrical outlet and pipe opening
(see Gas Pipe and Electric Outlet
may
be adjusted to meet
requirements.
. The range may be placed with O“ clearance
(flush) at the back wall and sidewalls of the range.
Do not
the
range where it may be subject
to strong drafts. Any openings in the floor or wall
behind the range should be sealed. Make sure
the openings around the base of the range that
supply fresh air for combustion and ventilation
are not obstructed by carpeting or woodwork.
PROTECT YOUR FLOOR
Your range, like many other household items, is
heavy and can settle into soft floor coverings
such as cushioned vinyl or carpeting. Use care
when moving the range on this type of flooring.
It is recommended that the following simple and
inexpensive instructions be followed to protect
your floor.
range should be
on a sheet of plywood
similar material).
the floor covering
the front
the area that the range
will rest on should be built up with plywood to
the same level or higher than the floor covering.
This will allow the range to be moved for cleaning
or servicing.
MODEL AND SERIAL NUMBER
Depending on your range, you’ll find the model
and serial numbers on a label on the front frame
of the range, behind the storage drawer, kick
panel or broiler drawer.
TOOLS YOU WILL NEED
●
Phillips and flat-blade screwdrivers
●
Pencil and ruler
●
Two pipe wrenches (one for backup)
. 1%” open-end or adjustable wrench
Nut drivers or wrenches: 3/16” and 1/4”
ADDITIONAL
YOU
NEED
●
Gas line shut-off valve
●
Pipe joint sealant or
pipe thread
tape with Teflon* that resists action of natural
and
gases
●
Flexible metal appliance connector (1/2” I. D.)
A 5-foot length is recommended for ease of
installation but other lengths are acceptable.
Never use an old connector when installing a
new range.
●
Flare union adapter for connection to gas
supply line (3/4” or
1/2”
1/2” I. D.)
●
Flare union adapter for connection to pressure
regulator on range (1/2”
1/2” I. D.)
*Teflon: Registered trademark of DuPont
.
Remove all tape and packaging. Lift up the
(on models with dual burners) and
remove any packing material under it. Make
sure the dual burners are properly seated
and level.
●
Remove plastic film that covers some chrome
parts (around oven door, side trim).
●
Take the accessory pack out of the oven.
●
Check to be sure that no range parts have
come loose during shipping.
30