37
Installation Instructions
SEAL THE OPENINGS
Seal any openings in the wall behind the
range and in the floor under the range when
hookups are completed.
4
ELECTRICAL CONNECTIONS (cont.)
When disconnecting the power cord from the
adapter, always hold the adapter with one
hand. If this is not done, the adapter ground
terminal is very likely to break with repeated
use. Should this happen,
DO NOT USE
the
appliance until a proper ground has again
been established.
Usage Situations where Appliance Power
Cord will be Disconnected Frequently.
Do not use an adapter plug in these situations
because disconnecting of the power cord
places undue strain on the adapter and leads
to eventual failure of the adapter ground
terminal. The customer should have the
2-prong wall receptacle replaced with a
three-prong (grounding) receptacle by a
qualified electrician before using the
appliance.
The installation of appliances designed for
mobile home installation must conform with
the Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD,
Part 280) or, when such standard is not
applicable, the Standard for Manufactured
Home Installations, latest edition
(Manufactured Home Sites, Communities and
Set-Ups), ANSI A225.1, latest edition, or with
local codes. In Canada, mobile home
installation must be in accordance with the
current CAN/CSA Z240/MH Mobile Home
Installation Code.
Electric Disconnect
•
Locate disconnect plug on the range back.
•
Pinch sides of connector and pull out of
range back.
B
3
LIGHT THE PILOTS
(For models equipped with standing pilots.
If the range is an electric ignition model, the
burners are ignited by electric ignition which
eliminates the need for standing pilot lights.)
The range should be installed in its permanent
position before any pilots are lit or adjusted.
Light the Surface Burner Pilots
1.
Raise the cooktop.
2.
Light both pilots with a match.
3.
To avoid pilot outage, use caution when
closing cooktop after lighting pilots.
NOTE:
Do not leave standing pilot lit in
a newly constructed or remodeled home or
apartment that will be unoccupied for more
than a month.
Each pilot flame was adjusted at the factory
to be approximately 5/16
″
tall. A tinge of yellow
appearing at the upper tip is normal. If you
find pilot adjustment is necessary, follow
instructions in Step B.
A
5
CAUTION
—
Make sure the surface burner
control knobs are in the
OFF
position before
attempting to light the pilots.
5/16
″