background image

TOOLS YOU WILL NEED

MATERIALS YOU MAY 

NEED

  Gas line shut-off valve

  Pipe joint sealant or UL-approved pipe thread 

tape with Teflon* that resists action of natural 

and propane gases

  Flexible metal appliance connector (1/2

 

I.D.). A 5-foot length is recommended for 

ease of installation but other lengths are 

acceptable. Never use an old connector 

when installing a new range.

  Flare union adapter for connection to gas 

supply line (3/4

 or 1/2

 NPT x 1/2

 I.D.)

  Flare union adapter for connection to 

pressure regulator on range (1/2

 NPT x 1/2

 

I.D.)

  Liquid leak detector or soapy water.

*Teflon: Registered trademark of DuPont

Flat-blade 

screwdriver

Pipe wrenches (2)

(one for backup)

Phillips 

screwdriver

Open-end or  

adjustable wrench

Pencil and ruler

Level

Drill, awl or nail

IN THE COMMONWEALTH 

OF MASSACHUSETTS

  This product must be installed by a licensed 

plumber or gas fitter.

   When using ball type gas shut-off valves, 

they shall be the T-handle type.

   A flexible gas connector, when used, must 

not exceed 3 feet.

Installation Instructions

Range

Questions? 

Call 800.GE.CARES (800.432.2737) or visit GEAppliances.com 

BEFORE YOU BEGIN

IMPORTANT —

 Save these 

instructions for local inspector’s use.

IMPORTANT —

 

Observe all 

governing codes and ordinances.

IMPORTANT —

 

Remove all packing 

material and literature from oven before 

connecting gas and electrical supply to range.

 

IMPORTANT —

 

To avoid damage 

to your cabinets, check with your builder 

or cabinet supplier to make sure that the 

materials used will not discolor, delaminate 

or sustain other damage. This oven has been 

designed in accordance with the requirements 

of UL and CSA International and complies 

with the maximum allowable wood cabinet 

temperatures of 194°F (90°C).

Note to Installer – Be sure to leave these 

instructions with consumer.

Note to consumer – Keep these instructions for 

future reference.

Servicer – The electrical diagram is in an 

envelope attached to the back of the range.

Proper installation is the responsibility of the 

installer. 

Product failure due to improper installation is 

not covered under warranty.

Before installing your range on linoleum or 

any other synthetic floor covering, make sure 

the floor covering can withstand 180°F without 

shrinking, warping or discoloring. Do not install 

the range over carpeting unless a sheet of 

1/4” thick plywood or similar insulator is placed 

between the range and carpeting.

Mobile Home - Additional Installation 

Requirements

The installation of this range must conform 

to the Manufactured Home Construction and 

Safety Standard, Title 24 CFR, Part 3280 

(formerly the Federal Standard for Mobile 

Home Construction and Saftey, Title 24, 

HUD Part 280). When such standard is not 

applicable, use the Standard for Manufactured 

Home Installations, ANSI A225.1/NFPA 501A 

or with local codes.

In Canada, the installation of this range must 

conform with the current standards CAN/CSA-

A240-latest edition, or with local codes.

When this range is installed in a mobile home, 

it must be secured to the floor during transit. 

Any method of securing the range is adequate 

as long as it conforms to the standards listed 

above.

WARNING

FIRE OR EXPLOSION 

HAZARD

If the information in this manual is not followed 

exactly, a fire or explosion may result causing 

property damage, personal injury or death.

Installation must be performed by a qualified 

installer.

Read these instructions completely and 

carefully.

Installation of this range must conform with 

local codes, or in the absence of local codes, 

with the National Fuel Gas Code, ANSI 

Z223.1/NFPA.54, latest edition. In Canada, 

installation must conform with the current 

Natural Gas Installation Code, CAN/CGA-

B149.1 or the current Propane Installation 

Code, CAN/CGA-B149.2, and with local codes 

where applicable. This range has been design-

certified by CSA International according to 

ANSI Z21.1, latest edition and Canadian Gas 

Association according to CAN/CGA-1.1 latest 

edition.

When installing a gas appliance the use of old 

flexible connectors can cause gas leaks and 

personal injury. Always use a 

NEW

 flexible 

connector.

Leak testing of the appliance shall be 

conducted according to the manufacturer 

instructions.

The range must be electrically grounded 

in accordance with local codes or, in the 

absence of local codes, in accordance with 

the National Electrical Code (ANSI/NFPA 70, 

latest edition). In Canada, electrical grounding 

must be in accordance with the current CSA 

C22.1 Canadian Electrical Code Part 1 and/or 

local codes. See Electrical Connections in this 

section.

Do not install this product with an air curtain 

hood or other range hood that operates by 

blowing air down on the cooktop.  This airflow 

may interfere with operation of the gas burners 

resulting in fire or explosion hazard.

FOR YOUR SAFETY:

•  A child or adult can tip the range and be killed.
•  Install the anti-tip bracket to the wall or floor.
•  Engage the range to the anti-tip bracket by sliding the 

  range back such that the foot is engaged.
•  Re-engage the anti-tip bracket if the range is moved.
•  Failure to do so can result in death or serious burns

  to children or adults.

Tip-Over Hazard

WARNING

WARNING

  

Before beginning 

the installation, switch power off at 

service panel and lock the service 

disconnecting means to prevent power 

from being switched on accidentally. 

When the service disconnecting means 

cannot be locked, securely fasten a 

prominent warning device, such as a 

tag, to the service panel.

If you did not receive an anti-tip bracket with your 

purchase, call 800.626.8774 to receive one at no 

cost. (In Canada, call 800.561.3344.) For installation 

instructions of the bracket, visit: 

GEAppliances.com

(In Canada, 

GEAppliances.ca.

)

Anti-Tip Bracket 

Kit Included

Summary of Contents for JGBS86EPES

Page 1: ...s ANSI A225 1 NFPA 501A or with local codes In Canada the installation of this range must conform with the current standards CAN CSA A240 latest edition or with local codes When this range is installed in a mobile home it must be secured to the floor during transit Any method of securing the range is adequate as long as it conforms to the standards listed above WARNING FIRE OR EXPLOSION HAZARD If ...

Page 2: ...NS DOUBLE OVEN GAS RANGE Recommended area for 120V outlet on rear wall and area for through the wall conection of pipe stub and shut off valve Recommended area for through the floor connection of pipe stub and shut off valve 4 1 2 4 2 8 5 3 14 1 2 9 30 43 1 2 26 3 4 w o handle 30 36 1 4 1 4 11 1 4 29 1 4 w handle CONVERTING TO PROPANE GAS OR CONVERTING BACK TO NATURAL GAS FROM PROPANE This range l...

Page 3: ...ll range controls are in the off position and turn on the main gas supply valve Use a liquid leak detector at all joints and connections to check for leaks in the system When using pressures greater than 1 2 psig to pressure test the gas supply system of the residence disconnect the range and individual shut off valve from the gas supply piping When using pressures of 1 2 psig or less to pressure ...

Page 4: ... device If not remove the unit and adjust the height of the rear leg so that it is properly engaged Spirit level X Y NOTE Cooktop must be at or above counter Grate Cooktop Counter 6 INSTALL AND CHECK ANTI TIP DEVICE WARNING Never completely remove the leveling leg as the range will not be secured to the anti tip device properly Follow instructions supplied with ANTI TIP bracket Anti Tip Bracket Ki...

Page 5: ...stalada en una casa móvil se deberá asegurar al piso durante el tránsito Cualquier método para asegurar la cocina es adecuado siempre y cuando se realice conforme con los estándares que figuran a continuación ADVERTENCIA RIESGO DE INCENDIO O EXPLOSIÓN Si la información de este manual no se sigue exactamente se podrá producir un incendio o explosión ocasionando daños sobre la propiedad lesiones o l...

Page 6: ... outlet on rear wall and area for through the wall conection of pipe stub and shut off valve Recommended area for through the floor connection of pipe stub and shut off valve 4 1 2 4 2 8 5 3 14 1 2 9 30 43 1 2 26 3 4 w o handle 30 36 1 4 1 4 11 1 4 29 1 4 w handle Sin manija Con manija CONVERTIR A GAS PROPANO O VOLVER A CONVERTIR DE PROPANO A GAS NATURAL Esta cocina deja la configuración de fábric...

Page 7: ...controles de la cocina estén en la posición de apagado y encienda la válvula de suministro principal de gas Use un detector de pérdida de líquido en todas las uniones y conexiones para controlar pérdidas en el sistema Al usar presión superior a psig para controlar la presión del sistema de suministro de gas de la residencia desconecte la cocina y la válvula de cierre individual de la tubería de su...

Page 8: ...correctamente adherida Nivel de Agua X Y NOTA La placa de cocción debe estar a la misma altura o más arriba que la mesada Rejilla Placa de Cocción Mesada 6 INSTALE Y CONTROLE EL DISPOSITIVO ANTIVOLCADURAS ADVERTENCIA Nunca retire completamente las patas niveladoras ya que la cocina no estará asegurada de forma adecuada al dispositivo antivolcaduras Siga las instrucciones suministradas con el sopor...