background image

DIMENSIONS AND 

CLEARANCES

Provide adequate clearances between the 

range and adjacent combustible surfaces. 

These dimensions must be met for safe use of 

your range. 
Allow 30” (76.2 cm) minimum clearance 

between burners and bottom of unprotected 

wood or metal cabinet, or allow a 24” (61 

cm) minimum when bottom of wood or metal 

cabinet is protected by no less than 1/4” (6.4 

mm) thick flame-retardant millboard covered 

with no less than No. 28 MSG sheet metal 

(.015” [.38 mm] thick), .015” (.38 mm) thick 

stainless steel, .025” (0.64 mm) aluminum or 

.020” (0.5 mm) copper.
Installation of a listed microwave oven or 

cooking appliance over the cooktop shall 

conform to the installation instructions packed 

with that appliance.
For island installation, maintain 2-1/2” 

minimum from cutout to back edge of 

countertop and 3” minimum from cutout to 

side edges of countertop.

Minimum to

cabinets on

either side

of the range.

Minimum

clearance

to left wall

Minimum

Minimum

clearance to

right wall

Maximum

depth for

cabinets above

countertops

Front edge of

the range side

panel forward

from cabinet

To cabinets below cooktop

and at the range back

To cabinets

below

cooktop and

at the range

back

18"

6"

30"

30"

13"

6"

36"

0"

0"

1/4"

GAS PIPE AND ELECTRICAL

OUTLET LOCATIONS

DOUBLE OVEN GAS RANGE

Recommended area for 120V

outlet on rear wall and area for

through-the-wall conection of

pipe stub and shut-off valve.

Recommended area

for through-the-floor

connection of pipe stub

and shut-off valve.

4 1/2"

4"

2"

8"

5"

3"

14 1/2"

9"

30"

43 1/2"

26 3/4"

w/o handle

30"

36 1/4" ± 1/4

11 1/4"

29 1/4"

w/ handle

A

B

D

E

F

G

H

C

30" 11 3/8"

43 3/4" 36 1/4" 30"

6"

6"

27"

CONVERTING TO PROPANE 

GAS 

(OR CONVERTING BACK 

TO NATURAL GAS FROM 

PROPANE)

This range leaves the factory set for use 

with natural gas. If you want to convert 

to propane gas, the conversion must be 

performed by a qualified propane gas 

installer.

The conversion orifices and instructions can 

be found on back of the range.
Keep these instructions and all orifices in 

case you want to convert back to natural gas.

Orifice Box 

(location 

may vary) 

INSTALLATION AT HIGH ALTITUDE

Over 6000ft, product configured for natural gas or propane requires installation of kit WB28X29254 

for natural gas and WB28X29255 for propane gas. Follow the instructions included with the kit.

DIMENSIONS AND CLEARANCES (CONT.)

GAS PIPE AND ELECTRICAL OUTLET LOCATIONS

CAUTION

 

To prevent 

drafts from affecting burner 

operation, seal all openings 

in floor under appliance and 

behind appliance wall.

18”

Minimum 

to cabinets 

above counter

0”

Minimum

to cabinets 

below 

cooktop

30”

Minimum 

30”

16”

Max to 

cabinets 

above 

counter 

3” Right side

6” Left side

Minimum 

to side wall

36”

30”

2”

5”

4”

9”

13”

14 1/2”

24”

4 1/2”

12 1/2”

Side Wall

Gas

and 

 

electrical

 

supply

Summary of Contents for JGBS86SPSS

Page 1: ...ANSI A225 1 NFPA 501A or with local codes In Canada the installation of this range must conform with the current standards CAN CSA A240 latest edition or with local codes When this range is installed...

Page 2: ...S DOUBLE OVEN GAS RANGE Recommended area for 120V outlet on rear wall and area for through the wall conection of pipe stub and shut off valve Recommended area for through the floor connection of pipe...

Page 3: ...l range controls are in the off position and turn on the main gas supply valve Use a liquid leak detector at all joints and connections to check for leaks in the system When using pressures greater th...

Page 4: ...device If not remove the unit and adjust the height of the rear leg so that it is properly engaged Spirit level X Y NOTE Cooktop must be at or above counter Grate Cooktop Counter 6 INSTALL AND CHECK A...

Page 5: ...es instalada en una casa m vil se deber asegurar al piso durante el tr nsito Cualquier m todo para asegurar la cocina es adecuado siempre y cuando se realice conforme con los est ndares que figuran a...

Page 6: ...outlet on rear wall and area for through the wall conection of pipe stub and shut off valve Recommended area for through the floor connection of pipe stub and shut off valve 4 1 2 4 2 8 5 3 14 1 2 9 3...

Page 7: ...ontroles de la cocina est n en la posici n de apagado y encienda la v lvula de suministro principal de gas Use un detector de p rdida de l quido en todas las uniones y conexiones para controlar p rdid...

Page 8: ...orrectamente adherida Nivel de Agua X Y NOTA La placa de cocci n debe estar a la misma altura o m s arriba que la mesada Rejilla Placa de Cocci n Mesada 6 INSTALE Y CONTROLE EL DISPOSITIVO ANTIVOLCADU...

Reviews: