background image

WHEN ALL HOOKUPS ARE 

COMPLETED

Make sure all controls are left in the off 

position. Make sure the flow of combustion and 

ventilation air to the range is unobstructed.

Check that all packing materials and tape 

have been removed. This will include tape on 

metal panel under control knobs (if applicable), 

adhesive tape, wire ties, cardboard and 

protective plastic. Failure to remove these 

materials could result in damage to the 

appliance once the appliance has been turned 

on and surfaces have heated.

7

 LEVEL THE RANGE

WARNING

 Never completely 

remove the leveling leg as the range will not 

be secured to the anti-tip device properly.
A.

  Plug in the unit.

B.

  Measure the height of your countertop at the 

rear of the opening (X).

C.

  Adjust two rear leveling legs so that the rear 

of cooktop is at the same height or higher 

than the counter (Y).

D.

  Slide unit into place.

E.

  Install oven shelves in the oven and position 

the range where it will be installed.

F.

  Check for levelness by placing a spirit 

level on one of the oven shelves. Take two 

readings—with the level placed diagonally 

first in one direction and then the other.

G.

  Adjust front leveling legs until the range is 

level.

H.

  Look under the unit and verify that the rear 

leg is fully engaged with the anti-tip device.  If 

not, remove the unit and adjust the height of 

the rear leg so that it is properly engaged.

Spirit level

X

Y

NOTE:

 Cooktop must be 

at or above counter.

Grate

Cooktop

Counter

6

 INSTALL AND CHECK 

ANTI-TIP DEVICE

WARNING

  Never completely 

remove the leveling leg as the range will not 

be secured to the anti-tip device properly.

Follow instructions supplied with ANTI-TIP 

bracket

Anti-Tip Bracket 

Kit Included

5

 CHECK BAKE AND BROIL BURNERS

  Set Bake function to 350°F. Burner should 

light in 30 to 60 seconds.

  Set broil to Broil Hi. Burner should light in 30 

to 60 seconds

4

 CHECK SURFACE 

BURNERS

Push and turn a knob to the LITE position. A 

clicking sound indicates proper operation of 

the ignition system. When lighting any burner, 

sparks will appear at all burners but gas flows 

from only the one selected. Once air is purged 

from the supply line, burner should light within 

4 seconds. After burner lights, rotate the knob 

out of the LITE position. Try each burner in 

succession until all burners have been checked.

Quality of Flames

Determine the quality of flames visually. Normal 

burner flames should look like (A) or (B).

Long, bright yellow flames are not normal. 

Normal flames may show signs of an orange 

tint when well heated or signs of flickering 

orange due to particles in the gas or air.

(A) Soft blue flames—

Normal for natural gas

(B) Yellow tips on 

outer cones—

Normal for propane gas

INSTALLATION INSTRUCTION

31-11005 Rev. 1   01-20   GEA

JGB860, JGBS86

Summary of Contents for JGBS86SPSS

Page 1: ...ANSI A225 1 NFPA 501A or with local codes In Canada the installation of this range must conform with the current standards CAN CSA A240 latest edition or with local codes When this range is installed...

Page 2: ...S DOUBLE OVEN GAS RANGE Recommended area for 120V outlet on rear wall and area for through the wall conection of pipe stub and shut off valve Recommended area for through the floor connection of pipe...

Page 3: ...l range controls are in the off position and turn on the main gas supply valve Use a liquid leak detector at all joints and connections to check for leaks in the system When using pressures greater th...

Page 4: ...device If not remove the unit and adjust the height of the rear leg so that it is properly engaged Spirit level X Y NOTE Cooktop must be at or above counter Grate Cooktop Counter 6 INSTALL AND CHECK A...

Page 5: ...es instalada en una casa m vil se deber asegurar al piso durante el tr nsito Cualquier m todo para asegurar la cocina es adecuado siempre y cuando se realice conforme con los est ndares que figuran a...

Page 6: ...outlet on rear wall and area for through the wall conection of pipe stub and shut off valve Recommended area for through the floor connection of pipe stub and shut off valve 4 1 2 4 2 8 5 3 14 1 2 9 3...

Page 7: ...ontroles de la cocina est n en la posici n de apagado y encienda la v lvula de suministro principal de gas Use un detector de p rdida de l quido en todas las uniones y conexiones para controlar p rdid...

Page 8: ...orrectamente adherida Nivel de Agua X Y NOTA La placa de cocci n debe estar a la misma altura o m s arriba que la mesada Rejilla Placa de Cocci n Mesada 6 INSTALE Y CONTROLE EL DISPOSITIVO ANTIVOLCADU...