36" and 30" cooktop/downdraft system counter installation
JVB98SH/94SH, JVB67H/37H
Note:
The countertop must be at least 26" deep with a flat surface area
of 23-1/2" or more, front to back. In addition, other clearances to the
front edge must be considered.
Note:
JP950S, JP940S, JP930S, JP910S, JGP940S require 23-5/8" flat
surface area.
Note:
See specific cutout illustrations with your cooktop model to
determine requirements.
Note:
A countertop with a raised or a rolled front edge may not allow
enough flat area for installation.
Planning Installation
Preparing Cutout
“A” Fig. 1
“B” Fig. 1
“B” & Vent Fig. 1
“C” Fig. 2
“D” Fig. 2
“E” Fig. 2
“F” Fig. 2
Overall
Min. required
Surface Depth
setback from
Cooktop
front edge
Countertop
Combined
Combined
Cooktop
Cooktop
Depth + Vent
to front edge
inside cabinet
Cutout
Cutout
36" Models
Overall Width Overall Depth
Cover Depth
of cutout
clearance
Width
Depth
Electric
JP980S/JP960S/JP970S
36-1/8"
21-1/4"
25 -1/4"
2-1/2"*
22-11/16"
33-7/8"
21-7/8"
JP980/JP960/JP970
36"
21-3/16"
24-5/8"
2-1/2"*
22-11/16"
33-7/8"
21-3/4"
JP655S
36-1/8"
20-7/16"
JP655
36"
20-3/8"
JP626
35-1/2"
21"
25-1/4"
2-1/2"
22-11/16"
33-7/8"
21-7/8"
Gas
JGP975/JGP963/
JGP637/JGP630/JGP628
36"
21"
25-1/4"
2-1/2"
22-11/16"
33-7/8"
21-7/8"
JGP970S
36"
21-1/4"
24-11/16"
2-1/2"*
22-11/16"
33-7/8"
21-3/4"
JGP970
36"
21-3/16"
24-11/16"
2-1/2"*
22-11/16"
33-7/8"
21-3/4"
30" Models
Electric
JP950S/JP940S/
JP930S/JP910S
29-7/8"
21-1/2"
25-3/4"
2-1/2"*
22-7/16"
28-1/2"
22-3/8"
JP950/JP940/
JP930/JP910
29-3/4"
21-7/16"
25-1/8"
2-1/2"*
22-7/16"
28-1/2"
22-1/4"
JP355
29-3/4"
20-7/8"
25-1/2"
2-1/2"
22-7/16"
28-1/2"
22-3/8"
JP340
29-3/4"
20-7/8"
25-1/2"
2-1/2"
22-7/16"
28-1/2"
22-3/8"
Gas
JGP933/JGP337/
JGP330/JGP328
30"
21"
25-1/4"
2-1/2"
22-7/16"
28-1/2"
22-3/8"
JGP940S
29-3/4"
21-3/8"
25-1/4"
2-1/2"*
22-7/16"
28-1/2"
22-1/4"
JGP940
29-3/4"
21-7/16"
25-1/4"
2-1/2"*
22-7/16"
28-1/2"
22-1/4"
JGP321
30-1/4"
21-1/4"
25-1/2"
3-1/4"
22-7/16"
28-1/2"
22-1/4"
* Raised edge bull nose countertops may require up to 3/8" additional clearance to prevent
interference with curved front.
Flat Surface Area
No Gas or Electric
Service Inside
Shaded Area
Island or
Peninsula*
G
D
H
J
I
D
1-7/8"
7"
2-1/8"*
Vent
F
E
C
Island or
Peninsula*
C
L
C
D
H
F
E
G
Cooktop
Minimum
Inside Cabinet
Clearance
Fig. 2
Overall Cutout Dimensions
No Gas or Electric
Service Inside
Shaded Area
Island or
Peninsula*
*These vents are recommended
for island installation. Against the
wall installations are limited due
to dimension requirements. Refer
to installation instructions, packed
with product, for further details.
K
= 34" For 36" Models
28-1/2" For 30" Models
J
= 29-1/2
J
= 32-1/4"
I
= 29-1/2"
E
F
K
J
** Includes 1/8" required
gap between cooktop
and vent trim.
Vent
D
2-1/4"
12-3/8"
Max.
6-3/8"
2-1/8"*
14-3/4"
27"
8-1/2" Lift
36"/30"
36"/30"
Vent
Dim. D to
Cutout
2-1/4
6-3/8
24-3/4
27
3/4" Thick
Support Rail
Cooktop
Downdraft Vent
7
12-3/8
6" Dia. or 3-1/4" x 10"
Rectangular Duct required.
24"
A
B
No Gas or Electric
Service Inside
Shaded Area
G
= 34" for 36" models
33-7/8" for 30" models
H
= 27-1/2"
No Gas or Electric
Service Inside
Shaded Area
Island or
Peninsula*
G
D
H
J
I
D
1-7/8"
7"
2-1/8"*
Vent
F
E
C
Island or
Peninsula*
C
L
C
D
H
F
E
G
Cooktop
Minimum
Inside Cabinet
Clearance
Fig. 2
Overall Cutout Dimensions
No Gas or Electric
Service Inside
Shaded Area
Island or
Peninsula*
*These vents are recommended
for island installation. Against the
wall installations are limited due
to dimension requirements. Refer
to installation instructions, packed
with product, for further details.
K
= 34" For 36" Models
28-1/2" For 30" Models
J
= 29-1/2
J
= 32-1/4"
I
= 29-1/2"
E
F
K
J
** Includes 1/8" required
gap between cooktop
and vent trim.
Vent
D
2-1/4"
12-3/8"
Max.
6-3/8"
2-1/8"*
14-3/4"
27"
8-1/2" Lift
36"/30"
36"/30"
Vent
Dim. D to
Cutout
2-1/4
6-3/8
24-3/4
27
3/4" Thick
Support Rail
Cooktop
Downdraft Vent
7
12-3/8
6" Dia. or 3-1/4" x 10"
Rectangular Duct required.
24"
A
B
No Gas or Electric
Service Inside
Shaded Area
G
= 34" for 36" models
33-7/8" for 30" models
H
= 27-1/2"
Required to
maintain U.L. or
AGA approvals.
* Includes 1/8" required gap
between cooktop and vent trim.