Page 1: ...ilure due to improper installation is not covered under the Warranty WARNING This appliance must be properly grounded FOR YOUR SAFETY WARNING If theinformation in this manual is not followed exactly a...

Page 2: ...sslyn VA 22209 This standard does not cover the thermal efficiency of household cooking gas appliances since it is regulated by the Energy Policy and Conservation Act of 1975 the National Energy Conse...

Page 3: ...ure the oven is installed at the specified height The unit has been tested and approved for installation in accordance with safety standards at this height If the floor is to be the solid bottom two r...

Page 4: ...on may create a hazardous condition Plug with ground prong properly polarized and grounded receptacle g Polarized receptacle properly grounded Metal Eyelet Ground Rece Plate Mountin Screw Preferred Me...

Page 5: ...G DO NOT USE OPEN FLAME TO CHECK FOR LEAKS r_ Apply a soap solution to all connections supply line manifold and oven _ Turn on the main gas supply _ Check for any bubbles to form _ Turn off main gas s...

Page 6: ...door F_ Remove the oven bottom Remove 4 screws to remove baffle flame spreader Oven Bottom _ _Fig 9 Burner Baffle_ F_ Remove orifice fitting cover Air Shutter Orifice Fitting Cover I 9 1MAKE THE BURN...

Page 7: ...screws provided secure the oven to the wall If the cabinet cutout is 38 high use the short trim and attach to the bottom of the front frame with screws provided If the cutout is higher than 38 use th...

Page 8: ..._ 11 i Fig 11 _ __ _1_ _ 1 t_ II II _i 11 _ Regulator t_ FLEXIBLE HOOK UP Cover Unscrewthe cap _ Cap Gasket Fig 12 Spring Retainer 4r Z NAT II I _ _ L R V I_ _ _ q _ F_r r _ q_ _ I I I I I I II II I I...

Page 9: ...4 WARNING youattemptto measure the inner cone of the flame please use caution burns could result ADJUST AIR SHUTTER NOTE The Bake and Broil burner flame must be checked with the door closed to properl...

Page 10: ...o loosen the air shutter adjustment screw 1 If the flames were yellow open the air shutter more than the original setting 2 If the flames blew away or fluttered from the burner close the air shutter m...

Page 11: ...nstalacion inadecuada no esta cubierta por la garantia _4 ADVERTENCIA Este aparato debe hacer tierra adecuadamente PARA SU SEGURIDAD iADVERTENCIA sila informacion en este manual no se sigue exactament...

Page 12: ...223 1 Latest Edition Para obtener una copia escriba a American Gas Association 1515 Wilson Boulevard Arlington Rosslyn VA 22209 Esta norma no cubre la eficiencia termal de los aparatos para cocinar a...

Page 13: ...dad ha sido probada y aprobada para la instalacion de acuerdo alas normas de seguridad a esta altura Si el piso va a ser el fondo solido dos soportes centrados a 11 uno del otro dentro del corte puede...

Page 14: ...a Enchufe con pata para hacer tierra polarizado adecuadamente y receptaculo que hace Fig 4 tierN _ Lra_ L IVletodo Preferido Receptaculo polarizado que hace tierra adecuadamente Ojo de metal para hace...

Page 15: ...LLAMA ABIERTA PARA VER Sl EXlSTEN ESCAPES DE GAS r_ Aplique una soluci6n de jab6n a todas las conexiones linea de abastecimiento caflerias y homo Abra el suministro principal del gas F_ Vea si se form...

Page 16: ...R r_ Abra la puerta del horno Saque el fondo del horno 1 _ Saque los 4 tornillos para remover el esparcidor de llamas Esl Fig 9 quemador fondo del horno I 9 ICOIVIO AJUSTAR LAS LLAMAS DEL QUEMADOR CON...

Page 17: ...oveen asegure el horno a la pared Si el corte del gabinete es de 38 de altura utilice la moldura corta y peguela al fondo del marco frontal con los tornillos que se proveen Si el corte es de mas de 38...

Page 18: ...I 1_ _ 1I 11 i i II _Cubierta delt_ Regulador I _ Destornille la tapa Tapa Fig 12 Sello _ Sujetadode _ Resorte NAT __lll _ L P _ _ AJUSTE EL REGULADOR DE PRESION DE GAS NATURAL A GAS L P CONT F_ Saque...

Page 19: ...iendola girar hacia L P AADVERTENCIA Sitrata de medir el cono interior de la llama por favor use precaucion se podria quemar AJUSTE EL OBTURADOR DE AIRE NOTA Las llamas para hornear y asar se deberian...

Page 20: ...no Use un destornillador para soltar el tornillo del ajuste del obturador de aire 1 Si las llamas estaban amarillas abra el obturador mas que la posicion original 2 Si las llamas soplaban en direccion...