background image

Specification Created 5/09

320371

JKP55SP 

GE

®

 27" Built-In Double Wall Oven

 

Dimensions and Installation Information 

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service, 

800.626.2000.

Listed by 

Underwriters 

Laboratories

 

 

KW Rating

 

240V

 

6.8

  208V

 

5.1

Breaker Size

 

240V

 

30 Amps

 

208V

 

30 Amps

Note:

 Cabinets installed adjacent to wall ovens must have 

an adhesion spec of at least a 194°F temperature rating.

Note:

 If marks, blemishes or the cutout opening is visible 

above the installed oven, it may be necessary to add 

wood shims under the runners and front trim until the 

marks or openings are covered.

Note:

 Door handle protrudes 3" from door face. 

Cabinets and drawers on adjacent 45° and 90° walls 

should be placed to avoid interference with the handle.

Electric wall ovens are not approved for installation 

with a plug and receptacle. They must be hard wired in 

accordance with installation instructions.

Cabinet 

27"

  A – Cabinet width required 

27" min.

  B – Minimum cabinet depth 

23-5/8"

 

C – Opening width 

25" min. - 25-1/4" max

  D – Opening height 

50-1/8" max

  E – Recommended minimum cutout location from floor 

13-1/4"

Oven 

 

  F –  Overall depth* 

23-5/8"

  G – Overall height with trim 

51-7/8" - 52-3/4"

   

Overall height without trim 

51"

  H – Overall width 

26-5/8"

*Depth including door handle is approximately 26-7/10" min. to 26-8/10" max.

CL

Suitable

bracing 

to support

runners

18" 

Over centerline

of cabinet

(must support 300 lbs.)

2" x  4" or

equivalent

runners

10

Locate

junction box

for 27"models

either 5" MIN.

below cutout

floor or 44"

MIN. above

cutout floor

Access 

from

adjacent 

cabinet

required

Allow 3/4" 

for overlap

over all edges

of cutout

A

Minimum

cutout location

from floor

D

E

2" X 4" or

equiv. runners

(cutout floor)

21" MIN.

door opening

allowance

B

C

H

F

G

Locate

junction box

for 24"models

56" MIN. above

cutout floor

Conduit

(48-1/2" Long)

21

Cabinet 

27"

  A – Cabinet width required 

27" min.

  B – Minimum cabinet depth 

23-5/8"

 

C – Opening width 

25" min. - 25-1/4" max

  D – Opening height 

50-1/8" max

  E – Recommended minimum cutout location from floor 

13-1/4"

Oven 

 

  F –  Overall depth* 

23-5/8"

  G – Overall height with trim 

51-7/8" - 52-3/4"

   

Overall height without trim 

51"

  H – Overall width 

26-5/8"

*Depth including door handle is approximately 26-7/10" min. to 26-8/10" max.

CL

Suitable

bracing 

to support

runners

18" 

Over centerline

of cabinet

(must support 300 lbs.)

2" x  4" or

equivalent

runners

10

Locate

junction box

for 27"models

either 5" MIN.

below cutout

floor or 44"

MIN. above

cutout floor

Access 

from

adjacent 

cabinet

required

Allow 3/4" 

for overlap

over all edges

of cutout

A

Minimum

cutout location

from floor

D

E

2" X 4" or

equiv. runners

(cutout floor)

21" MIN.

door opening

allowance

B

C

H

F

G

Locate

junction box

for 24"models

56" MIN. above

cutout floor

Conduit

(48-1/2" Long)

21

Dimension and installation information are shown in inches.