Note:
The source unit configuration settings are stor
ed in the “clipboard”
and may be applied to unlimited number of destination units of the same
type.
Note:
The user is allowed to modify the selections prior to pressing the
Configure button.
Note:
The user may opt not to apply the changes to the destination unit in
which case the Cancel button shall be selected after the Paste action.
Main Tab
When a VistaNET connection (local or network) to the unit is established, the unit
view is displayed with its Main Tab selected. The content of the Main Tab is
shown in Figure 36.
Unit Info
Status
Displays the status of the left and right Line Ports for each provisioned
TDM pipe.
32
Note that the alarm conditions applicable to the Line Port
signal as a whole are simultaneously displayed for all provisioned TDM
pipes on the port. The possible display values (shown in priority order)
are:
Clock Fail
– Line port is not connected;
CBW Rate
– The local Line Port Mode setting (see Line Setup tab)
is not matching the CBW port mode set on the JMUX unit
33
.
AIS
– Path AIS is detected in at least one received STS-1 SPE;
Bad BER
– Path (B3) error rate exceeds threshold in at least one
received STS-1 SPE;
Mismatch
– Indicates one of the following:
-
At least one of the received STS-1 SPEs is not from an ETHER-
1000
34
or ETHER-100 unit, or
-
At least one of the received STS-1 SPEs has been assigned to
a wrong TDM pipe (at either or both ends), or
-
The far-end unit is not set to use the same number of SPE slots
for this TDM pipe
35
, or
32
See
Line Setup
tab for information on how to provision a TDM pipe.
33
If the Line Port is connected to a cascaded ETHER-1000 unit, this indicates that the Line Port
Mode settings on the two units are not matching.
34
This alarm will appear at both ends of the STS-1 path interconnecting V1 and V3 ETHER-1000
units if it belongs to a TDM pipe with more than 16 provisioned STS-1 paths.