g

 

Product Data Sheet – rev 4.2 
July 4th 2003  
Page 12 
 
 

 

LightSpeed

16

 

 

With Xtream 

CT Scanner System 

GE Medical Systems-America 
Milwaukee, USA  - Fax: 1 414 544 3384 
GE Medical Systems-Asia: 
Tokyo, Japan - Fax: 81 425 85 5490 
Hong Kong - Fax: 852 2559 3588 
GE Medical Systems-Europe 

do not support DICOM Print may require a 
filming interface (purchased separately). 

To save further filming cost, the Operator 
Console can directly print to a postscript 
printer such as the GE Color Printer available 
as an option. 

ImageWorks 

ImageWorks software is designed to take 
advantage of the Lightspeed

16

 CT Scanner’s 

computer and image processor. This desktop 
environment includes image management and 
networking. 

Because some of the image analysis and 
display features of ImageWorks replicate 
those in Exam Rx, the next section describes 
only features that are incremental or 
significantly different. 

Image Analysis 

• 

Multi-Projection Volume 

Reconstruction

 (MPVR): Quick and easy 

way to generate volumetric images for CT 
angiography without thresholding data or 
removing unwanted anatomy. An entire 
volume is used to generate images in any 
plane, creating real-time frames of 
reference at the same time;  

• Clinical utility is extended via two 
additional modes:  

 MIPS - enhances contrast and improves 

visualization of calcifications 

 Average - generates 2D radiographic 

images; 

• 

Multi-planar Reformation

 (MPR): 

Provides real-time assessment of anatomy 
in offaxis planes. Sagittal, coronal, oblique 
and curved planar reformations available; 

• 

Batch reformatting

 can also be defined 

and executed for later viewing if desired; 

• Image Addition and Subtraction: Includes 
image addition of more than two images at 
a time;  

 

*Volume Viewer 

Volume Viewer is an innovative and 
powerfull suite of productivity enhanvers 

(Volume Rendering, Volume Analysis and 
Navigator) that includes :

 

• 

Dynamic Volume Review™ for Fast 
Screening 

• 

Curved Volume Of Interest 

• 

Protocol Management and Loading 

• 

Review Layout Presets 

• 

Multiple VR Objects Merge 

• 

Pseudo Surface Shading Mode 

• 

Predefined Cut Planes 

• 

Volume Rendered Navigator views 

• 

VR Preset save/recall 

• 

3D Rendered Lumen View 

• 

Automatic Path Tracking 

• 

Path Bridging (in case of occlusions) 

• 

SmartCursor™ for Easy Navigation 

• 

Synchronized Reformatted Views 

• 

Cut visualization mode

 

 

 

*Advanced Vessel Analysis 

Advanced Vessel Analysis is the ultimate 
tool to assess and quantify vascular 
structures, including stenosis analysis, 
stent planning procedures, post stenting or 
vascular surgery follow-up. 

• 

protocol driven tools to perform quick, 
flexible and accurate quantitative analysis of 
vascular anatomy 

• 

provides maximum, minimum and mean 
intraluminal diameter measurements  

• 

provides cross-sectional areas of true 
orthogonal sections of the aortoiliac systems 
at selected anatomical points 

• 

clinical benefits include: stenosis sizing, pre- 
and post- surgical assessment, stent 
planning 

• 

Measurements in % stenosis or mm of 
stenosis, and measurement of length and 
dimension of stenosis.  

 

Image Display 

• 

Magnifying Glass allows quick 2X mag 
window that can be moved over an image. 

• 

Image Scroll moves an image within its’ own 
window. 

• 

Groupings allow application of window/level 
values, magnification/minification, image 

scroll or flip and rotate to a user-defined 
image set. 

• 

Save State stores user-selected image 
orientation and window/level with each data 
set. 

• 

Window/Level values may be: 

• 

Preset to provide six on-screen instant 
window/level settings 

• 

Set independently for up to 16 images on 
the screen 

• 

User-modified in discrete or variable 
steps 

• 

Adjusted real-time on-image by holding 
down the middle mouse button and 
moving the mouse 

• 

Cine mode provides paging in up to 4 view 
ports of up to 128 previously-stored CT or 
MR images at full selected display frame 
rate.  For more than 128 images, display 
frame rate may be reduced. 

• 

Cine mode also provides temporal, spatial 
or manual playback loops. 

• 

Text Page 

Image Annotation 

• 

Image annotation and cursor are shadowed 
to permit ease in reading. 

Image Management 

• 

Images may be stored and retrieved via 
Magnetic Optical Drive (MOD) media using 
DICOM 3.0 format. This allows interchange 
with other imaging systems supporting 
DICOM 3.0 MOD media. Not all vendors 
implementation of DICOM 3.0 are identical, 
so please check with the manufacturer for 
compatibility. 

• 

Off-line retrieval of all image files. Images 
may be viewed as soon as they are restored 
from MOD.

 

• 

Image retrieval time is approximately 30 
images 512 per second.

 

VariViewer

TM

• 

VariViewer is an interactive axial review 
mode that can change the slice thickness 
reconstruction instantaneously. 

• 

The user selects the volume to be 
specifically analyzed and chooses the slice 
thickness to be displayed as axial images. 
The user can then save a number of recon 
images sets, viewing a large number of 
slices for pure axial review and filming. 

* Option 

Summary of Contents for LightSpeed 16

Page 1: ...o provide an optimized workflow solution from acquisition to final report Lowest dose acquisition using SmartmA TM an automatic modulation technique and DLP display that tells the operator the dose before the scan starts HyperPlane TM reconstruction algorithm tackles the inherent issues with fast high pitch helical scanning by reducing helical artifacts and dose and optimizing the slice profile Cr...

Page 2: ... may allow you to reduce contrast media perform better thin slice CT angiography exams use thinner slices for most exams and perform longer helical exams without tube cooling delays Remote Gantry Tilt from the Operator s Console to increase exam speed including built in safety features to prevent accidental contact of the gantry with the patient CTDIw DLP Dose Length Product and Dose Efficiency di...

Page 3: ...exam to the patient All console components monitors keyboard mouse and BrightBox are free standing and can be easily moved on the front work surface Large 1024 color display Patient demographics and exam protocols can be preprogrammed in advance of patient arrival through the Schedule Patient feature Leading edge real time image processing MPR MPVR Volume Viewer All surfaces made of high impact re...

Page 4: ...ontinue with additional helical scans or a set of axial scans Helical 8 SLICE HELICAL MODES Table Speed mm rotation Slice Thick ness mm Pitch 0 625 1 0 875 1 1 35 1 1 675 1 1 25 6 25 8 75 13 5 16 75 2 5 6 25 12 5 8 75 17 5 13 5 27 0 16 75 33 5 3 75 6 25 12 5 8 75 17 5 13 5 27 0 16 75 33 5 5 6 25 12 5 8 75 17 5 13 5 27 0 16 75 33 5 7 5 6 25 12 5 8 75 17 5 13 5 27 0 16 75 33 5 10 6 25 12 5 8 75 17 5...

Page 5: ...16 slice recon mode Ten user defined regions Each region has one default protocol displayed with the anatomical selector for very fast access to most commonly used protocols Scan Speeds Full 360 rotational scans in 0 5 0 6 0 7 0 8 0 9 1 0 seconds Maximum image to image cycle time is 10 for prospective and retrospective image to image display This applies for 512 matrix any display FOV in AutoView ...

Page 6: ...413 Prospective Recon Operator may initiate full recons at any table location in increments of 1 10 the image thickness image thickness remains constant 0 5mm Retrospective Recon Operator may initiate full recons at any table location in 0 1 mm increments image thickness remains constant Retrospective Image Decomposition The operator has the option to retrospectively decompose the original raw dat...

Page 7: ...e increment Gantry display in 0 5 mm increments On 8 inch 20 cm CATPHAN phantom 5 mm 3 at 13 3 mGy 3 mm 3 at 37 2 mGy For each rotation of the gantry the LightSpeed 16 collects 16 rows of scan data There are five reconstruction modes available for creating images from the multi slice scan data 1i 2i 4i 8i and 16i By using 1i 2i 4i and 8i reconstruction modes scan data can be combined prior to imag...

Page 8: ...r to acquisition The operator can select different reconstruction algorithms and display fields of view for each reconstruction This frees the operator from sitting at the console and directly contributes to increased productivity Standard Scans On GE Performance phantom Scan Time ISD mA Scans Acquisition Time 1 sec 1 sec 440 18 45 0 35 1 27 1 1 400 24 55 0 47 1 49 1 1 360 32 68 1 03 2 15 1 1 340 ...

Page 9: ...aker microphone and volume controls CTDIvol expressed in mGy 100 mAs Three button mouse with mouse pad The ImageWorks desktop also provides a gateway for DICOM 3 0 image transactions either through a local area network or via DICOM formatted MOD media Head 18 4 mGy 100 mAs Body 9 3 mGy 100 mAs BrightBox trackball assembly Two wide work surfaces Scout Scans All these devices are free standing and c...

Page 10: ...removed from the prescription Scan recon control uses only 2 screens to set up first scan New Patient and Protocol View Edit Dose Computation Display CTDIvol CTDI volume DLP Dose Length Product and Dose Efficiency computation and display during scan prescription provides patient dose information to the operator Protocol View Edit A single full screen View Edit table allows fast and easy examinatio...

Page 11: ...lows full use of the image display monitor for AutoView and image review processing without interruption during AutoFilm Gray Scale Enhancement An AutoFilm Composer provides a simple programming interface for automated filming set up ProView visualization algorithms are available to enhance anatomical structures without additional reconstruction time Batch Filming is accomplished through a single ...

Page 12: ...is is the ultimate tool to assess and quantify vascular structures including stenosis analysis stent planning procedures post stenting or vascular surgery follow up protocol driven tools to perform quick flexible and accurate quantitative analysis of vascular anatomy provides maximum minimum and mean intraluminal diameter measurements provides cross sectional areas of true orthogonal sections of t...

Page 13: ... sec and 40 mm sec System Components Horizontal Range 170 cm Horizontal Scannable Range 170 cm metal free axial and 160 cm metal free helical Scout Gantry Image transfer time using either AdvantageNet or DICOM 3 0 protocols is approximately 0 1 second per 512 image on a 100baseT Network Horizontal Speed Up to 100 mm sec Advanced slip ring design continuously rotates generator tube detector and dat...

Page 14: ... disk drive Average time to replace tube 10 hours High Performance Drive 2GB DDR266 Dual Channel Memory with a throughput of 4 2GB sec 36 GB 3 5 inch form factor High Voltage Generation UltraSCSI interface Image Processor High frequency on board generator Continuous operation during scan Standard MOD drive Nvidia Quadro4 980XGL AGP 8X graphics with 128MB Memory Magnetic Optical Disk Drive 53 2 kW ...

Page 15: ...time and receive pull query and storage commitment push Siting Requirements Minimum Suite Size AdvantageNet GenesisNet point to point send receive and pull query no broadcast Overall Suite Compatible UPS options are available if desired 15 5 feet 4 74 m wide x 19 5 feet 5 96 m deep x 9 feet 2 75 m high InSite point to point Cooling Requirements TCP IP for system administration Recommended Suite Si...

Page 16: ...ight 1 887 74 1 Table Width 610 24 Length 5 050 199 Height 1 120 44 Power Distribution Unit Width 762 30 Depth 585 23 Height 1 270 50 Operator Console Width 1 238 48 7 Depth 1 288 50 7 Height 1 257 49 5 Warranty The published Company warranty in effect on the date of shipment shall apply The Company reserves the right to make changes All specifications are subject to change Regulatory Compliance T...

Page 17: ...4th 2003 Page 17 LightSpeed16 With Xtream CT Scanner System GE Medical Systems America Milwaukee USA Fax 1 414 544 3384 GE Medical Systems Asia Tokyo Japan Fax 81 425 85 5490 Hong Kong Fax 852 2559 3588 GE Medical Systems Europe Option ...

Page 18: ...htSpeed16 With Xtream CT Scanner System GE Medical Systems America Milwaukee USA Fax 1 414 544 3384 GE Medical Systems Asia Tokyo Japan Fax 81 425 85 5490 Hong Kong Fax 852 2559 3588 GE Medical Systems Europe Minimum Room Layout Typical Room Layout Option ...

Reviews: