Connect the two quick connectors and 

reassemble the connector box.

Load springs into upright position by twisting the 

springs upward and carefully insert the fixture to 

the hole of the frame. Verify reflector trim is flush 

with ceiling.

Reassemble 

connector box

Connect plugs:

3 pole to 3 pole

2 pole to 2 pole

Springs up

 CAUTION

RISK OF PERSONAL INJURY - 

Operators shall ensure no 

appendages are in the path of the torsion springs 

as they are a pinch hazard when released. The 

springs will release when the arm is flexed downward. 

Be cautious that no body part is in the path of the 

spring when released.
RISQUE DE BLESSURE CORPORELLE - Les techniciens 

veilleront à ce qu’aucun appendice ne se trouve sur 

le chemin des ressorts de torsion, car ils présentent 

un risque de pincement lorsqu’ils sont libérés. Les 

ressorts seront libérés au moment de fléchir le bras vers 

le bas. Faites attention à ce qu’aucune partie du corps 

ne se trouve sur le chemin du ressort à sa libération.

19

20

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, 
and (2) this device must accept any interference received, including interference that may cause undesired operation. CAN ICES-005 (A) / NMB-005 (A).

Note: 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are 

designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment 
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful 
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be 
required to correct the interference at his own expense.

Summary of Contents for Lumination RC Series

Page 1: ...quement Save These Instructions Use only in the manner intended by the manufacturer If you have any questions contact the manufacturer Prepare Electrical Wiring Electrical Requirements The LED luminaire must be connected to the mains supply according to its ratings on the product label Grounding Instructions The grounding and bonding of the overall system shall be done in accordance to local elect...

Page 2: ...on L brackets Mounting brackets 3 Slide hanger bars through adjustable mounting brackets 4 Option A Mount fixture by attaching hanger bars to T Grid ceiling BH3 SKU 94890 Option B Mount fixture with EMT conduit Note Supplied by 3rd party Bars Conduit A B Adjust height and tighten wing nut 5 Adjust fixture height to be flush with ceiling and tighten both mounting bracket wing nuts Components Provid...

Page 3: ...C Wiring Diagram DRIVER TPC Black Red Lead White Lead Black Lead White Lead L N G PSU Enclosure Blue Lead 0 10V Purple Dimming Lead 0 10V Grey Dimming Lead Black Lead 120V ONLY Red Lead 277V ONLY NOTE Through Wiring for RC series 15A Circuit Lumen Level Maximum Number of Fixtures 120V Input 277V Input 1000 84 195 1500 77 179 2000 59 138 3000 38 89 4000 24 57 Minimum Spacing Requirements for all Fi...

Page 4: ...hang freely Plug together the light fixture to the driver enclosure with the supplied quick connects and assemble the connector housing when finished Feed button stop and toggle through hole in bracket Safety tether Button stop Toggle Assembled connector housing Connect two quick connects Cut cable tie on light fixture Position fixture so L bracket does not interfere with springs Align the fixture...

Page 5: ...e se trouve sur le chemin du ressort à sa libération 17 Load springs into upright position by twisting the springs upward and carefully insert the fixture to the hole of the frame Ensure fixture is secure Springs up 16 Connect the two quick connectors and reassemble the connector box Reassembled connector box Connect plugs Final installation position for springs Push fixture through the hole in th...

Page 6: ... and gray dimming wires to the violet and gray wires of the fixture NOTE Please cover dimming leads with wire nuts if you won t connect with dimming leads Dimming compatibility for both 0 10V and phase cut please refer to GE website www gelighting com dimming AC line 18 0 10 Volt Dimming Gray 0 10V 0 10V Violet To 0 10V Dimmer LED Driver Wiring Diagram L Dimming N Dimming Ground LRX Fixture Black ...

Page 7: ... chemin des ressorts de torsion car ils présentent un risque de pincement lorsqu ils sont libérés Les ressorts seront libérés au moment de fléchir le bras vers le bas Faites attention à ce qu aucune partie du corps ne se trouve sur le chemin du ressort à sa libération 19 20 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not...

Reviews: