background image

GE Energy

Industrial Solutions

Air Circuit Breakers
400 - 4000A

M-PACT Plus

 

ED.03

  

GE imagination at work

Summary of Contents for M-Pact Plus

Page 1: ...GE Energy Industrial Solutions Air Circuit Breakers 400 4000A M PACT PlusED 03 GE imagination at work...

Page 2: ......

Page 3: ...000A Technical overview Order codes Wiring diagrams Dimensional drawings Numerical index A B C X A 4 Fixed circuit breaker A 6 Withdrawable circuit breaker A 7 Characteristics A 9 Electronic trip unit...

Page 4: ...A 2 M PACT Plus A B C X M PACT Plus M PACT Plus Air Circuit Breaker 400 4000A...

Page 5: ...415V AC 2 compact frame sizes Frame size 1 400 to 2500A Frame size 2 800 to 4000A Fixed pattern and withdrawable versions 3 or 4 pole versions Front and rear access connections horizontal vertical De...

Page 6: ...e interlocking optional Termination rear horizontal or front access optional Electrical clearances according to IEC 60947 2 Front access of secondary terminals for simple connection Installation Fixed...

Page 7: ...zontal vertical connection optional Front access connections optional Automatic disconnect of secondary circuits Lifting lugs for ease of removing the circuit breaker from the cassette Front access of...

Page 8: ...nt 40 C In A 400 630 800 1000 Endurance n of operating cycles 20000 20000 20000 20000 Mechanical with maintenance 10000 10000 10000 10000 Mechanical without maintenance 5000 5000 5000 5000 Electrical...

Page 9: ...4P Neutral on the left or right Please specify on selection form the default option is Neutral on right Catalogue Number Con guration 1200 1600 2000 2500 3200 4000 20000 20000 20000 20000 20000 20000...

Page 10: ...igns covering an extended functionality with protection devices as fuse links overload protection and reduced instantaneous RELT Each MPRO 50 comes with a simple to connect 4 wire modbus communciation...

Page 11: ...Possibility to switch OFF X X Selective execution X X Fixed instantaneous or HSIOC protection X X Reduced Ii setting range from 1 5 to 15 x Ie primary setting X Steps of 0 5 a total of 29 settings X...

Page 12: ...vice Set at 0 6 x Ie of 2500A Ig 1500A Band GFDB 6 I t ON OFF 2h 7 2 x Green Light Blue Line Full Clearing time Red Line Dark Blue Line Non Tripping time LT Band ST Band I I Band HSIOC Band GF Band Ti...

Page 13: ...0 975 0 9625 0 95 0 45 or 0 4 x In Ir 0 4 1 x Ie in steps of 0 25 Total Setting Range 0 2 1 x In Time Current Curve Band C 03 Band C 08 Band C 13 Band C 19 LT Protection Device Time Current Curve Band...

Page 14: ...Setting Range Ie 0 975 0 9625 0 95 0 45 or 0 4 x In Ir 0 4 1 x Ie in steps of 0 25 Total Setting Range 0 2 1 x In Time Current Curve Band C 05 Band C 10 Band C 15 Band C 21 LT Protection Device Time...

Page 15: ...time I protection set to 15 Ie 1 I protection set to 15 Ie 1 ST set at Breaker Rating In 1 5 to 12 Ir in steps of 0 5 Setting Range ST set at Breaker Rating In 1 5 to 12 Ir in steps of 0 5 Setting Ra...

Page 16: ...13 11 9 7 5 3 1 16 16 14 14 12 12 10 10 8 8 6 6 4 2 4 2 17 15 13 11 9 7 5 3 1 Time Current Curve Band STDB 01 Band STDB 03 Band STDB 05 Band STDB 07 Band STDB 09 Band STDB 11 Band STDB 13 Band STDB 15...

Page 17: ...s 1 00 10 00 10 0 8 0 6 0 4 0 2 0 1 0 01 0 10 Tripping Time In Seconds s x Breaker rating In 1 00 10 00 10 0 8 0 6 0 4 0 2 0 1 0 01 0 10 Tripping Time In Seconds s x Breaker rating In GF set on breake...

Page 18: ...GFDB 05 Band GFDB 07 Band GFDB 09 Band GFDB 11 Band GFDB 13 GF Protection Device I2 t low ON Time Current Curve Band GFDB 02 Band GFDB 04 Band GFDB 06 Band GFDB 08 Band GFDB 10 Band GFDB 12 Band GFDB...

Page 19: ...aker rating In 0 1 to 1 In in steps of 0 01 Setting Range Time Current Curve Band GFDB 01 Band GFDB 03 Band GFDB 05 Band GFDB 07 Band GFDB 09 Band GFDB 11 Band GFDB 13 GF Protection Device I2 t max ON...

Page 20: ...is instigat ed should a closing signal be maintained Because each coil operates within a wide voltage range the number of individually rated coils required is drastically reduced Shunt trip Energisat...

Page 21: ...tions Key interlock facility Ready to t interlocking device Ronis for installation between separate circuit breakers available in kit form This valuable safeguard ensures that a circuit breaker cannot...

Page 22: ...installed the carriage switch is IP2X protected and includes wiring to a terminal block located on the left hand side of the cassette Note The carriage position switch is an option only suitable for w...

Page 23: ...Circuit breaker B2 can only close if B1 is open Type B Interlocking between 3 circuit breakers 3 power supplies generator or transformers feeding the same busbar but parallel operation is prevented Av...

Page 24: ...y locked in position thus preventing access to the contacts and also ensuring that the racking mechanism is not operable For lock and key details refer to key interlock facility section p A 21 Sealed...

Page 25: ...130 Auxiliary power unit 110 220 380 110 220 Plug in Portable Test Unit PTU Specially designed for reliable testing of the MCR and HSISC protection systems on each phase by means of tertiary injectio...

Page 26: ...A 24 M PACT Plus A B C X Notes...

Page 27: ...A Non automatic B 6 Air circuit breaker type S 50kA Automatic B 8 Air circuit breaker type N 65kA Non automatic B 10 Air circuit breaker type N 65kA Automatic B 12 Air circuit breaker type H 80kA Non...

Page 28: ...B 2 Order codes A B C X M PACT Plus Notes...

Page 29: ...ures Mechanical Operation Counter Mechanical Trip Alarm Switch 1NO Portable Test Unit Auxillary Power Unit 110V AC DC 220V AC DC Auxillary Contactor 5NC 3NC 4NC 4NC 9 Control Voltage MOP CC ST UV UVTD...

Page 30: ...405125 MS32F40 405155 4 Left MS4L2W40 405124 MS4L2F40 405154 4 Right MS4R2W40 405338 MS4R2F40 405393 Front access connections Withdrawable TOP connections BOTTOM connections Frame size Rating A Poles...

Page 31: ...0 2 3200 3 MS32M32 405823 4 Left MS4L2M32 405824 4 Right MS4R2M32 405592 2 4000 3 MS32M40 405825 4 Left MS4L2M40 405826 4 Right MS4R2M40 405594 Earthing device Frame size Rating A Poles Cat no Ref No...

Page 32: ...4R2F32 A 405748 2 4000 3 MS32W40 A 406199 MS32F40 A 405277 4 Left MS4L2W40 A 406200 MS4L2F40 A 405276 4 Right MS4R2W40 A 406282 MS4R2F40 A 405786 Air circuit breaker type S 50kA Automatic Frame 1 2 Pl...

Page 33: ...4 Right MS4R2M25 A 406214 2 3200 3 MS32M32 A 405941 4 Left MS4L2M32 A 405942 4 Right MS4R2M32 A 406216 2 4000 3 MS32M40 A 405943 4 Left MS4L2M40 A 405944 4 Right MS4R2M40 A 406218 Earthing device Fra...

Page 34: ...MN4L2W32 405182 MN4L2F32 405212 4 Right MN4R2W32 405466 MN4R2F32 405490 2 4000 3 MN32W40 405185 MN32F40 405215 4 Left MN4L2W40 405184 MN4L2F40 405214 4 Right MN4R2W40 405468 MN4R2F40 405492 Air circu...

Page 35: ...52 4 Right MN4R2M25 405632 2 3200 3 MN32M32 405853 4 Left MN4L2M32 405854 4 Right MN4R2M32 405634 2 4000 3 MN32M40 405855 4 Left MN4L2M40 405856 4 Right MN4R2M40 405636 Earthing device Frame size Rati...

Page 36: ...53 MN32F32 A 405783 4 Left MN4L2W32 A 405452 MN4L2F32 A 405782 4 Right MN4R2W32 A 406042 MN4R2F32 A 406126 2 4000 3 MN32W40 A 405455 MN32F40 A 405785 4 Left MN4L2W40 A 405454 MN4L2F40 A 405784 4 Right...

Page 37: ...4 Left MN4L2M25 A 405984 4 Right MN4R2M25 A 406238 2 3200 3 MN32M32 A 405989 4 Left MN4L2M32 A 405990 4 Right MN4R2M32 A 406240 2 4000 3 MN32M40 A 405991 4 Left MN4L2M40 A 405992 4 Right MN4R2M40 A 40...

Page 38: ...c Frame 2 Basic circuit breaker manually operated non automatic switch only no protection unit option available 5 NO and 3 NC auxiliary switches Withdrawable pattern basic circuit breaker and cassette...

Page 39: ...6 405644 2 2000 3 MH32M20 405875 4 Left MH4L2M20 405876 4 Right MH4R2M20 405646 2 2500 3 MH32M25 405877 4 Left MH4L2M25 405878 4 Right MH4R2M25 405648 2 3200 3 MH32M32 405883 4 Left MH4L2M32 405884 4...

Page 40: ...pe H 80kA Automatic Frame 2 Please select trip unit type in page B 16 Basic circuit breaker manually operated automatic must be fitted with an MPRO Protection Unit as listed on page B 16 5 NO and 3 NC...

Page 41: ...A 406250 2 2000 3 MH32M20 A 406005 4 Left MH4L2M20 A 406006 4 Right MH4R2M20 A 406252 2 2500 3 MH32M25 A 406007 4 Left MH4L2M25 A 406008 4 Right MH4R2M25 A 406254 2 3200 3 MH32M32 A 406009 4 Left MH4L...

Page 42: ...N Dual GF protection Res SUM or CT GFDB Relt Instantaneous I Modbus Communiction RELT Input supply 24V DC 1 Extended functionality MPRO 50H trip unit For Frame 1 GQ100M7 6SF 408873 LT band choice LT C...

Page 43: ...es SUM or CT GFDB Relt Instantaneous I Modbus Communiction RELT Input supply 24V DC 2 Extended functionality MPRO 50H trip unit For Frame 1 GQ100M7 6SF 408885 LT band choice LT C or LT F LT C 0 4 1 x...

Page 44: ...405408 380 440V AC UV440 405409 Undervoltage release Time Delayed UVTD 48V DC UVTD48 406322 110 130V AC UVTD130 406326 220 250V AC UVTD250 405411 380 440V AC UVTD440 405413 Carriage switch Factory tt...

Page 45: ...ixed 3 C23WCIF23PF 405495 4 C23WCIF24PF 405497 Mechanical accessories Type A 2 way interlock Cable Type B 1 from 3 way interlock Cable Frame size Version Poles Cat no Ref No Cat no Ref No 1 Withdrawab...

Page 46: ...73 1 800 to1600 N and 1600 S N 2 CLCN116 405770 1 2000 to 2500 N 2 CLC125 405771 2 3200 N 2 CLC232 405772 2 4000 N 2 CLC240 405773 2 800 to 3200 H 2 CLC232 405772 2 4000 H 2 CLC240 405773 Universal Cl...

Page 47: ...C 1 M PACT Plus A B C X C 2 MPRO 27 50 Connection Scheme C 3 Dimensional drawings Technical overview Order codes Wiring diagrams Dimensional drawings Numerical index...

Page 48: ...Unit MPRO 50 N RC A15 A14 N RC N Relay O P3 Relay O P4 A 2 A 1 A 4 A 3 B 5 B 6 24V 24V 24 VDC EL CT B 3 B 4 Interposing CT A12 A11 A10 A 9 1 2 3 4 Input 1 4 A13 C A20 A19 RX RX Communication A16 SCR A...

Page 49: ...m of breaker connections busbars or cables All connections to be tightened to 50Nm Minimum space to earth metal and for arc chute removal Insulated metal or insulated sheet customer supplied Centre li...

Page 50: ...l Centre line of operating panel Copperwork must be supported within 200 mm of breaker connections busbars or cables All connections to be tightened to 50Nm Copperwork must be supported within 200 mm...

Page 51: ...nsulated metal or insulated sheet customer supplied Horizontal rear access connection Fixed pattern Type S N 3 pole Frame size 1 In 2000A to 2500A Type S N 4 pole Frame size 1 In 2000A to 2500A Centre...

Page 52: ...f operating panel Centre line of operating panel Centre line of operating panel Copperwork must be supported within 200 mm of breaker connections busbars or cables All connections to be tightened to 5...

Page 53: ...tightened to 50Nm Centre line of operating panel Centre line of operating panel 35 Test 50 Disconnected 275 Fully withdrawn Connected Ventilation Minimum clearance to cassette side to door Copperwork...

Page 54: ...s busbars or cables All connections to be tightened to 50Nm Centre line of operating panel Centre line of operating panel 35 Test 50 Disconnected 275 Fully withdrawn Connected Ventilation Minimum clea...

Page 55: ...sbars or cables All connections to be tightened to 50Nm to door Center line of operating panel Center line of operating panel 50 Disconnected 35 Test 275 Fully withdrawn Connected Ventilation Minimum...

Page 56: ...ected to door Ventilation Minimum clearance to cassette side Copperwork must be supported within 200 mm of breaker connections busbars or cables All connections to be tightened to 50Nm Must not be rem...

Page 57: ...arc chute removal 100 to door Minimum clearance to breaker side Copperwork must be supported within 200 mm of breaker connections busbars or cables All connections to be tightened to 50Nm Center line...

Page 58: ...Center line of operating panel Minimum clearance to breaker side Copperwork must be supported within 200 mm of breaker connections busbars or cables All connections to be tightened to 50Nm Insulated m...

Page 59: ...al 100 to door Center line of operating panel Center line of operating panel Minimum clearance to breaker side Copperwork must be supported within 200 mm of breaker connections busbars or cables All c...

Page 60: ...within 200 mm of breaker connections busbars or cables All connections to be tightened to 50Nm Minimum clearance to breaker side Center line of operating panel Center line of operating panel Center li...

Page 61: ...inimum clearance to cassette side Connected Disconnected Test to door Copperwork must be supported within 200 mm of breaker connections busbars or cables All connections to be tightened to 50Nm Center...

Page 62: ...panel Center line of operating panel Minimum clearance to cassette side Connected Disconnected Test to door Copperwork must be supported within 200 mm of breaker connections busbars or cables All con...

Page 63: ...C 17 M PACT Plus Front access connection A B C X Adaptor connections Rear Adapter Vertical Connection Rear Adapter Horizontal Connection Rear Adapter Vertical Horizontal Connection...

Page 64: ...s Fixed and or withdrawable Copper connections Rear access withdrawable Type S Frame 1 ln 400A to 2500A max Type N Frame 1 ln 400A to 2500A max Type S N Frame 2 ln 3200A to 4000A max Type H Frame 2 ln...

Page 65: ...ole 4 pole 4 pole 3 pole 3 pole A A A A Cassette mounting details Type S N Frame 1 ln 400A to 2500A max Type S N Frame 2 ln 3200A to 4000A max Type H Frame 2 ln 800A to 4000A max A recommended install...

Page 66: ...ve give an approximate nominal clearance of 30mm around ACB fascia These sizes are for guidance and can be scaled if different aperture is required Escutcheon LLA11PD055 Escutcheon seal LLA11RS001 ACB...

Page 67: ...r access Min bend radius 120 Min bend radius 120 900 Max vertical base to base Frame 1 3P 322 Frame 1 4P 422 Frame 2 3P 410 Frame 2 4P 540 Min clearance below cassette Min clearance below cassette Min...

Page 68: ...M PACT Plus A B C X Notes...

Page 69: ...X 1 M PACT Plus A B C X X 2 Numerical index by reference number X 4 Numerical index by catalogue number Technical overview Order codes Wiring diagrams Dimensional drawings Numerical index...

Page 70: ...25 B 5 405343 MS31C25 B 5 405344 MN41C25 B 9 405345 MN31C25 B 9 Ref no Cat no Page 405346 MN42C32 B 9 405347 MN32C32 B 9 405348 MN42C40 B 9 405349 MN32C40 B 9 405350 MN4L1W04 A B 10 405351 MN31W04 A B...

Page 71: ...05851 MN32M25 B 9 405852 MN4L2M25 B 9 405853 MN32M32 B 9 Ref no Cat no Page 405854 MN4L2M32 B 9 405855 MN32M40 B 9 405856 MN4L2M40 B 9 405858 MH4L2W25 A B 14 405859 MH32W25 A B 14 405860 MH4L2W32 A B...

Page 72: ...t no Ref no Page 1 100BCMCI 405531 B 19 160BCMCI 405532 B 19 2 200BCMCI 405533 B 19 250BCMCI 405610 B 19 2WCI3PF 406340 B 19 2WCI3PW 406342 B 19 2WCI4PF 406341 B 19 2WCI4PW 406343 B 19 2WCIF23PF 40546...

Page 73: ...A 406256 B 15 MH4R2M40 405652 B 13 MH4R2M40 A 406258 B 15 MH4R2W08 405494 B 12 MH4R2W08 A 406130 B 14 MH4R2W10 405496 B 12 MH4R2W10 A 406134 B 14 Cat no Ref no Page MH4R2W12 405498 B 12 MH4R2W12 A 40...

Page 74: ...405912 B 7 MS4L1M12 405812 B 5 MS4L1M12 A 405914 B 7 MS4L1M16 405814 B 5 MS4L1M16 A 405916 B 7 MS4L1M20 405816 B 5 MS4L1M20 A 405918 B 7 MS4L1M25 405818 B 5 MS4L1M25 A 405920 B 7 MS4L1W04 405102 B 4 M...

Page 75: ......

Page 76: ...Energy Industrial Solutions 1101 City Tower 2 Sheikh Zayed Road P O Box 11549 Dubai Tel 971 43131202 United Kingdom GE Energy Industrial Solutions Houghton Centre Salthouse Road Blackmills Northampton...

Reviews: