A.16
T
echnical ov
er
view
A
B
C
X
M-PACT Plus
MPRO 27 & 50 Electronic Trip Unit
MPRO 27 & 50 Electronic Trip Unit
MPRO 27 & 50 Electronic Trip Unit
MPRO 27 & 50 Electronic Trip Unit
1,00
10,00
10
1
0,8
0,6
0,4
0,2
0,1
0,01
0,10
Tripping Time In Seconds (s)
x Breaker rating In
1,00
10,00
10
1
0,8
0,6
0,4
0,2
0,1
0,01
0,10
Tripping Time In Seconds (s)
x Breaker rating In
1,00
10,00
10
1
0,8
0,6
0,4
0,2
0,1
0,01
0,10
Tripping Time In Seconds (s)
x Breaker rating In
1,00
10,00
10
0,8
0,6
0,4
0,2
0,1
0,01
0,10
Tripping Time In Seconds (s)
x Breaker rating In
GF set on breaker rating In
0,1 to 1 × In in steps of 0,01
Setting Range
GF set on breaker rating In
0,1 to 1 × In in steps of 0,01
Setting Range
GF set on breaker rating In
0,1 to 1 × In in steps of 0,01
Setting Range
- Time Current Curve
- Band GFDB 01
- Band GFDB 03
- Band GFDB 05
- Band GFDB 07
- Band GFDB 09
- Band GFDB 11
- Band GFDB 13
GF- Protection Device
I
2
t “low” -ON-
- Time Current Curve
- Band GFDB 02
- Band GFDB 04
- Band GFDB 06
- Band GFDB 08
- Band GFDB 10
- Band GFDB 12
- Band GFDB 14
GF- Protection Device
I
2
t “low” -ON-
13
13
13
11
9
7
5
3
1
11
9
7
5
3
1
14
14
12
12
10
10
8
6
4
2
8
6
4
2
14
14
12
10
8
6
4
2
12
10
8
6
4
2
11
9
7
5
3
1
13
11
9
7
5
3
1
Green Iine = Full Clearing time
Red Line = Non Tripping time
Green Iine = Full Clearing time
Red Line = Non Tripping time
Green Iine = Full Clearing time
Red Line = Non Tripping time
Green Iine = Full Clearing time
Red Line = Non Tripping time
- Time Current Curve
- Band GFDB 01
- Band GFDB 03
- Band GFDB 05
- Band GFDB 07
- Band GFDB 09
- Band GFDB 11
- Band GFDB 13
GF- Protection Device
I
2
t “med” -ON-
GF set on breaker rating Inv
0,1 to 1 × In in steps of 0,01
Setting Range
- Time Current Curve
- Band GFDB 02
- Band GFDB 04
- Band GFDB 06
- Band GFDB 08
- Band GFDB 10
- Band GFDB 12
- Band GFDB 14
GF- Protection Device
I
2
t “med” -ON-
Time Current Curves (cold state) - GF Protection Device