24
MDS entraNET Technical Manual
05-4055A01, Rev. E
• hardware flow control disabled
• VT100 emulation
NOTE:
The
exact
parameters given above must be used for console
terminal communication. Improper settings are a common
cause of difficulty.
Invisible place holder
Invisible place holder
Invisible place holder
Invisible place holder
Invisible place holder
Figure 2-6. Remote Configuration Setup
3. Press
several times to receive the
entranet>
prompt (the
COM1
/
ETH
LED blinks to indicate data communication).
4. At the
entranet>
prompt, enter
login
. Press
.
5. At the next prompt, enter the username (the default username is
admin
). Press
.
6. At the next prompt, enter the password (the default password is
admin
). Press
. The radio is now ready to accept commands.
Set or Verify Network Address
The only setting normally required for initial checkout of a Remote
radio is the network address. All radios in a given network
must
be
programmed with the same network address as the AP, or
communication is impossible. Follow the steps below to check the
address, and program a new one if necessary.
1. Enter the
RADIO NETADDR=
command. This displays the currently
programmed network address.
2. If changes are required, enter the
RADIO NETADDR=<netaddr>
com-
mand, where
<netaddr>
is 1 to 15 alphanumeric characters (the net-
work address of the Remote radio
must
match that of the AP).
3. Verify that the
LINK
LED lights to indicate successful connection
with the AP (it might take several seconds for the LED to light).
ENTER
ENTER
ENTER
ENTER
Summary of Contents for MDS entraNET 900
Page 10: ...LA N CO M1 CO M2 PW R LIN K viii MDS entraNET Technical Manual 05 4055A01 Rev E...
Page 12: ...2 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Page 24: ...14 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Page 26: ...16 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Page 38: ...28 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Page 110: ...100 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Page 130: ...120 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Page 156: ...146 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Page 158: ...148 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Page 176: ...166 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Page 186: ...176 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Page 188: ...178 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Page 204: ...194 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Page 218: ...I 8 MDS entraNET Technical Manual 05 4055A01 Rev E...