Additional Considerations for Mobile Operation
Consider the following key points for all mobile installations:
• Use connectionware—The use of connectionware in the mobile lap-
tops is highly recommended for better operation of a mobile data
system. GE MDS provides connectionware from one of the vendors
in this market. Contact your factory representative for details.
• Plan your network coverage—Deploy Access Points so that they
provide overlapping coverage with each other. Access Points must
use the same Network Name to enable roaming service.
• Set the RSSI Threshold to -85 dBm—This level is typically used for
mobile systems with good performance. Make sure there is overlap-
ping coverage of more than one AP to provide continuous coverage.
• At every AP Radio, review the following settings when providing
service to mobile remotes:
•
TDD Sync
—Set to
GPS Required
.
•
Pattern Offset
—Each AP should be different. Cell planning is
required if there are overlaps.
•
Hop Pattern
—Set the same on all APs.
•
Compression
[
disabled
]—Disable radio compression. Data com-
pression is best performed by the connectionware running on
the mobile laptop PC. Gains in efficiency are made because
connectionware compresses data at a higher stack level, and it
aggregates multiple data frames and streams into a single
packet. Compression at the radio level, although highly effi-
cient, works only at the individual packet level.
Summary of Contents for MDS Mercury Series
Page 2: ......
Page 10: ...2 Mercury Reference Manual 05 4446A01 Rev C ...
Page 28: ...20 Mercury Reference Manual 05 4446A01 Rev C ...
Page 36: ...28 Mercury Reference Manual 05 4446A01 Rev C ...
Page 140: ...132 Mercury Reference Manual 05 4446A01 Rev C ...
Page 142: ...134 Mercury Reference Manual 05 4446A01 Rev C ...
Page 156: ...148 Mercury Reference Manual 05 4446A01 Rev C ...
Page 168: ...160 Mercury Reference Manual 05 4446A01 Rev C ...
Page 184: ...176 Mercury Reference Manual 05 4446A01 Rev C ...
Page 194: ...I 10 Mercury Reference Manual 05 4446A01 Rev C ...