MobileView User Manual
3 DVR Installation and Wiring
1036564B / October 2002
21
3.2.3 A
LARM AND
T
RIGGER
I
NPUTS
The MobileView system allows for six inputs, which can be defined as either triggers (events) or alarms.
The Impact Sensor and Panic Button are examples of alarm inputs. When a trigger or an alarm is
activated, it will open the normally closed connection. Refer to the system specific layout for the location
and types of inputs used in your installation.
1)
Remove the J11 terminal block (
in Figure 24) from the back box by loosening its mounting
screws and pulling it out of its socket.
2)
Strip each wire 3/8 inch (9.5 mm).
3)
Connect each trigger device as shown in Figure 28; each trigger device must have a normally
closed connection with the DVR.
Note:
Terminal 18 also can be used for a panic button or an impact sensor (up to three wires can go into terminal 18).
3.2.3.1 I
MPACT
S
ENSOR
C
ONNECTIONS
The Impact Sensor’s N/C wire (green or white) and common wire (black) connect to one of the pairs of
input terminals shown in Figure 29. Its 12 VDC wire (red) connects to terminal 18.
Figure 29. Impact Sensor input connections
Input 1
Input 3
Input 5
Auto shutdown
Input 2
Input 4
Input 6
Figure 28. Alarm/trigger connections to J11 terminal block
Summary of Contents for MobileView