ZDBC240NBS –  GE Monogram Stainless Steel Beverage Center

Dimensions and Specifications (in inches)
Installation Space

The Monogram

®

 Beverage Center may be installed beneath a  

countertop or can be used free-standing.
•  If installing between frameless cabinets, a 1/2"-wide filler strip 

or side panel may be required. The filler strip will act as a spacer 

between the door case and adjacent cabinet and will prevent  

interference with cabinet door swing. The width of the opening  

must include filler panels.

Note:

 When installed, the door should project forward 1" of  

adjacent 24"-deep cabinets.

Location Requirements

All Monogram Refrigeration Modules may be closed in on the top  

and sides as long as the front is unobstructed for air circulation and 

door swing.
•  Do not install these products where the temperatures will go  

below 55°F (13°C) or above 90°F (32°C).

•  Do not install where they will be subject to direct sunlight,  

heat or moisture.

• These products are not designed to be stacked one over the other.

For answers to your Monogram,

®

 GE Profile

 or  

GE

®

 appliance questions, visit our website at  

GEAppliances.com or call GE Answer Center

®

  

service, 800.626.2000.

Listed by 

Underwriters 

Laboratories

34-1/2"-35"

24" Min.

23-3/4" 

25-1/2"

Including

Handle

23-3/4"

1-1/2" 

Locate Outlet 

9"  

Max.

10-1/2" 

23-3/4" Min. 

34-1/4"

to

34-3/4"

Side-by-Side Installation

For a complete refreshment center, install a Monogram Wine Reserve 

and Beverage Center together.
•  Products must operate from separate properly grounded  

receptacles.

Door Swing Clearances

All Monogram Refrigeration Modules are factory set for a 110°  

door swing.

When installed in a corner:

• Allow the minimum door swing clearances shown.
•  The minimum clearance shown at 90° will allow full extension  

of drawers and shelves.

A

Minimum to Wall  

110

°

110

°

 Door  

Swing

21-5/8"

23-5/8"

B

Minimum to Wall

90

°

90

°

 Door  

Swing

10"

Minimum to Wall

4"

Minimum to Wall

Electrical

A 120V, 60Hz, 15 or 20 amp power supply is required. An individual 

properly grounded branch circuit or circuit breaker is recommended. 

Install a properly grounded 3-prong electrical recessed into the  

back wall as shown. Electrical must be located on rear wall as shown.

Note:

 GFCI (ground fault circuit interrupter) is not recommended.

Specification Revised 4/06