Electrical Requirements

Ranges must be supplied with 208/240V, 60Hz, and connected to 

an individual, properly grounded branch circuit protected by a circuit 

breaker or time-delay fuse. Install a 50-amp circuit for 48" ranges.  

The receptacle must be a NEMA 14-50R device to accept the  

four-prong  plug on the range.

Optional Backsplash Accessories

The range requires a 12" minimum clearance to a vertical combustible 

surface at the rear. A backsplash is required for installations with  

less than 12" clearance. The following backsplash accessories are 

available, or a custom, non-combustible backsplash can be used

Backsplashes: Order one with a 48"-wide range 

ZX12B48HSS

–12" backsplash

ZX22B48HSS

– 22" backsplash with warming shelf

Backsplash with Warming Shelf

All Monogram Professional Wall-Mounted Hoods feature infrared 

warming lights. The 22"-high backsplash with warming shelf is  

a perfect complement when installed with the tapered or  

straight-sided hoods.
 If you choose to install this range with a Restaurant-Style  

Professional Hood (ZV48RSFSS), no additional accessories are  

required. These hoods are shipped with a stainless steel  

backsplash and warming shelf.

Side View with a Backsplash

Gas Supply

•  Natural gas models are designed to operate at 5" water column 

pressure. A regulator is required at the natural gas source to  

provide maximum of 7" water pressure to the range regulator.

•  The liquid propane models are designed to operate at 10" water 

column pressure. A regulator is required at the LP source to provide 

maximum of 14" water pressure to the range regulator.

Locate gas and  

electric as shown

8"

4"

8"

12"

16"

Gas 

Supply

48"

1-1/2"

4"

Electric

Supply

605Dia60

Backguard

36" Min. 

to 

Combustibles

0" Clearance

12" Min. to Combustibles or 

0" Min. to Combustibles

with 12" or 22" Backsplash