background image

Created 7/97

Monogram.

UL

R

Listed by
Underwriters
Laboratories

For answers to your GE Monogram,

GE Profile,

GE, Hotpoint and RCA appliance questions, call 
GE Answer Center

®

service, 800.626.2000.

ZGG36N31YSS–36” Outdoor Cooking Center

Dimensions and Specifications (in inches)

Installation in a non-combustible enclosure.

• In a non-combustible (masonry) enclosure, the grill drops into the

opening and hangs from its side flanges. A deck is not required
for support.

3" Min. for Lid
Clearance

34-1/2"

18-1/2"

22-3/4"

9-1/8"

24-1/8"

18-1/4"

4x4 Opening
for Gas Supply
Line

Opening
for Access
Doors

If Installing
an Electrical
Outlet for
the Rotisserie
Motor, Mount
on Right Side
(6.5 AMP Min.)

35-1/2"

Max.

3" Min. for Lid
Clearance

40-1/2"

18-1/2"

3-1/8"

23-3/4"

10-1/8"

24-1/8"

18-1/4"

4x4 Opening
for Gas Supply
Line

Opening
for Access
Doors

If Installing
an Electrical
Outlet for
the Rotisserie
Motor, Mount
on Right Side
(6.5 AMP Min.)

35-1/2"

Max.

Installation in a combustible enclosure. 
ZX36JYSS insulated jacket is required.

• Combustible enclosures require insulated jackets. 

ZX36JYSS for 36” models and ZX48JYSS for 48” models. The 
insulated jacket must be supported from the bottom by a solid
deck or ledge on each side beneath the jacket.

• Construct the enclosure as shown and place the insulated jacket

into the enclosure. Place the cooking center into the jacket. No
installation hardware is required.

Clearances - All Models

• Allow 3” at the rear for lid clearance.

• Allow at least 12” clearance at the back of the grill when

exhaust is directed to a window or a surface that is
difficult to clean.

• Allow at least 6” clearance on each side to any non-combustible

material located above the cooking surface for counterspace.
Rotisserie models also require 6” clearance for placing and
handling the motor and skewer.

• Allow at least 12” clearance on each side to combustible 

vertical materials.

Reviews: