Installation Instructions
21
STEP 8 SECURE UNIT TO WALL
Standard and Stainless Installation Only
• The “L” rods can be found in the upper left and right
corners of the unit in the access compartment. Look
through the access compartment to make sure the rods
line up with the anti-tip bracket.
• There are 2 washers and a hair pin cotter per rod.
Remove the washers and hair pin cotter from the end of
the rod.
• Rotate and move the “L” rod into the slot in the anti-tip
bracket tab. Once it is in the slot, rotate the “L” rod so
the hook portion is pointing down. The holes at the front
end of the rod should be in a vertical position. Do this to
both sides.
• Pull out on the end of the rod to make sure it is secure in
the bracket.
• Locate the hole on the rod that is closest to the unit. A
hair pin cotter will be put through this hole to secure the
rod. If this hole appears to be too far away for a snug fit
against the unit, add the washers one at a time until the
pin will fit tightly into the hole.
• Align the straight section of the pin with the hole from
the underside of the rod. Push the pin up until it snaps
into position. Pliers may be used. NOTE: The hair pin
cotter must be vertical when this step is completed to
ensure the “L” rod is engaged in the bracket.
• Check the rod for tightness by pulling forward. If the rod
moves, remove the hair pin cotter and place another
washer on the rod. Reinsert the pin.
• Replace the grille panel.
Summary of Contents for Monogram ZIRS360NNLH
Page 30: ...Notes 30...
Page 31: ...Notes 31...