6
Installation Preparation
36" Stainless Steel Refrigerators, Freezers
Electrical
and Water
Connection
Locations
The water line can be routed through the floor or
back wall.
• The icemaker water line should be:
– Approximately 3-1/2" from the floor on the back wall,
or 3-1/2" from the back wall on the floor.
– At least 5" from either side of the opening.
A 115 volt, 60 Hz 15 or 20 amp power supply is
recommended. An individual properly grounded
branch circuit or circuit breaker is recommended,
as noted on the rating plate.
• Locate the electrical outlet within 5" x 6" shaded area
shown.
– 2-1/2" from the left side.
Between 75" and 81" from the floor.
IMPORTANT:
To insure a flush fit and access to the
power cord, locate the electrical outlet as shown.
Clearances
Factory set for a 130
°
door swing. Order WX14X99
adjustable door stop to reduce swing to as little as 90
°
.
When Installed into a corner:
Allow 25" for a full 130
°
door swing. Allow 15" for pan
removal. Allow 4" min. clearance when door swing is
adjusted to a 90
°
opening for pan access, but pan
removal is restricted.
Clearances for two products installed side-by-side
with right and left side hinges together
Allow 5" minimum between the two products to prevent
one door from striking the other. Use the WX14X99
adjustable door stop to reduce the factory set 130
°
door swing and to allow pan removal.
NOTE:
ZUGSS Grille Panel Kit will not fit this installation.
25"
Min. to
Wall
130
°
130
°
Door
Swing
36-3/4"
4" Min.
to Wall
90
°
Door Swing
25"
Min. to
Wall
0"
25"
Min. to
Wall
130
°
Door
Swing
130
°
Door
Swing
Clearances for Multiple Single Door Installations
In a side-by-side installation of a left and right door
swing product, no clearance between the units is
required. Order ZUGSS Stainless Steel Unified Grille
Panel Kit for one continuous grille panel.
Clearances for two products installed side-by-side
with the same (left or right) door swing
Allow 2" minimum clearance between the products to
prevent door swing interference. Order the WX14X99
adjustable door stop to reduce the factory set 130
°
door swing. Allow 15" minimum to a wall to achieve
full drawer extension and pan removal.
NOTE:
ZUGSS Grille Panel Kit will not fit this installation.
2"
15"
5"
Water Location
3 1/2"
5"
6"
5"
Electrical Outlet
Location 2 1/2"
75"