CHAPTER 1: PRODUCT DESCRIPTION
SPECIFICATIONS
MULTISYNC 100 GPS CLOCK – INSTRUCTION MANUAL
5
Testing and certification
APPROVALS AND CERTIFICATION
IEC 61850-3 EMI TYPE TESTS
Compliance
Applicable council directive
According to
CE compliance
Low voltage directive
EN60950-1
EMC directive
EN61000-6-2
EN61000-6-4
North America
cULus
UL60950-1
C22.2 No. 60950-1
CB Report including all country deviations
ISO
Manufactured under a registered
quality program
ISO 9001:2008
Test
Description
Test Levels
Severity
Levels
IEC 61000-4-2
ESD
Enclosure C/- 8 kV
4
Enclosure Air
+/- 15 kV
4
IEC 61000-4-3
Radiated RFI
Enclosure Ports
20 V/m
IEC 61000-4-4
Burst
D.C. Power port
+/-4 kV
4
IEC 61000-4-5
Surge
Signal Ports
+/- 4kV line to earth,
+/- 2kV line to line
4
D.C. Power Ports
+/- 2kV line to earth,
+/- 1kV line to line
3
IEC 61000-4-6
Induced RFI
Signal Ports
10 V
3
D.C Power ports
10 V
3
Earth Ground
Ports
10 V
3
IEC 61000-4-8
Magnetic Field
Enclosure Ports
40 A/m continuous,
1000A/m for 1s
IEC 61000-4-29
IEC 61000-4-11
Voltage Dips and
Interrupts
D.C. Power ports
30% for 0.1s, 60% for 0.1s,
100% for 0.05s
IEC 61000-4-12 Damped Oscillatory
Signal Ports
D.C. Power ports
2.5kV common, 1kV diff,
mode @1MHz
3
IEC 61000-4-16 Mains Frequency
Voltage
Signal Ports
D.C. Power ports
30V Continuous,
300V for 1s
4
IEC 61000-4-17 Ripple on D.C. Power
Supply
D.C. Power ports
10%
3
IEC 60255-5
Dielectric Strength
Signal Ports
2 kVAC
(fail-safe relay output)
D.C. Power ports
2 kVAC
IEC 60255-5
H.V. Impulse
Signal Ports
5 kV (fail-safe relay output)