6
MULTISYNC 100 GPS CLOCK – INSTRUCTION MANUAL
SPECIFICATIONS
CHAPTER 1: PRODUCT DESCRIPTION
IEEE 1613 (37.90.X) EMI IMMUNITY TYPE TESTS
ENVIRONMENTAL TYPE TESTS
Test
Description
Test Levels
IEEE 37.90.3
ESD
Enclosure C/-2 kV, +/-4 kV, +/- 8 kV
Enclosure Air
+/-4 kV, +/-8 kV, +/- 15 kV
IEEE 37.90.2
Radiated RFI
Enclosure Ports
35 V/m
IEEE 37.90.1
Fast Transient
Signal Ports
+/-4 kV @2.5kHz
D.C. Power Ports
+/-4 kV
IEEE 37.90.1
Oscillatory
Signal Ports
2.5kV common mode
@1MHz
D.C Power ports
2.5 kV common, 1 kV diff.
mode @1MHz
IEEE 37.90
H.V. Impulse
Signal Ports
5 kV (fail-safe relay output)
D.C. Power ports
5 kV
IEEE 37.90
Dielectric Strength
Signal Ports
2 kVAC
D.C. Power ports
2 kVAC
Test
Description
Test Levels
IEC 60068-2-1
Cold Temperature
Test Ad
-40°C, 16 hours
IEC 60068-2-2
Dry Heat
Test Bd
+85°C, 16 hours
IEC 60068-2-30 Humidity (Damp Heat,
Cyclic)
Test Db
95% (non-condensing),
55°C, 6 cycles
IEC 60255-21-1 Vibration
2 g at 10-150 Hz
IEC 60255-21-2 Shock
30 g @ 11 mS