Output options
TTL
Programmable pulses: .....................................From 1000 per second to 1 per day with programmable
offset & duration
DCF-77:....................................................................DC level shift
Local or universal time
IRIG-B:.......................................................................DC level shift or Modified Manchester
IEEE 1344 extensions (C37.118)
AFNOR NF S87-500 extensions
Local or universal time
Networking
GENERAL
DHCP:........................................................................Auto-configuration with fallback to ARP tested link-local
address
VLAN: ........................................................................packet tagging
PTP (IEEE 1588 V2)
General: ...................................................................One-step or two-step operation
End-to-end or peer-to-peer delay calculations
Layer 2 (Ethernet) or Layer 3 (UDP) transport
Slave only mode
Default Profile support
Power Profile support: ......................................C37.238
TLV support:...........................................................C37.238 offset from TAI time base used by PTP
Alternate Time Offset TLV support: ............with automatic or manual offset
SNMP MIB support:.............................................C37.238
NTP
General: ...................................................................Stratum-1 NTP & SNTP time server
Multicast & Broadcast server capability
Optional MD5 authentication
SNMP
General: ...................................................................V1, V2C, and V3 support, independently enabled
Configurable V1 and V2C community names and security
groups
Fully configurable via SNMP
V3 User-based Security Module (USM) support
USM MIB support
USM authentication methods:......................MD5, SHA
USM privacy methods:......................................DES, AES
NOTIFICATIONS
General: ...................................................................SNMP trap generation V1, V2C, and V3
SNMPv3 traps authenticated and privatized via USM
Syslog (RFC-3164 and 5424 verities)
Environmental specifications
OPERATING ENVIRONMENT
Ambient Temperature: .....................................-40° to 140 °F (-40° to 60 °C) for UL 60950 and Component
Parts
-40° to 195 °F (-40° to 85 °C) for IEC 60068 Type Test short
term rating
Storage Temperature:.......................................-40° to 185 °F (-40° to 85 °C)
Ambient Relative Humidity:............................5% to 95% (non-condensing)
Altitude:....................................................................Up to 6560 feet (2000 m)