Installing the IVG-400 

If the IVG-400 is connected directly to the vehicle battery, it continues operating 
even when the engine is turned off.  For example, with a 55AMP/h battery, the 

system will continue to function for about 10 hours if the vehicle battery is not 
recharged. 
If the IVG-400 is connected through the ignition switch, it will only operate when 
the ignition is on.  Bear in mind, also, that it will take a few minutes for the IVG-

400 to boot up after the ignition is switched on and about 2.5 minutes after the 
ignition is switched off. 

Installing the IVG-400 

To install the IVG-400: 

1.

 

Connect the two side supports (Figure 4) to either side of the body of the 
IVG-400, using three screws for each support, as in Figure 5.  (The screws 

are included with the IVG-400.) 

 

Figure 4 - Side support 

 

Figure 5 - Side supports attached to IVG-400 body 

Screw 

Side support 

IVG-400 body 
(upside down)

2.

 

Place the unit in the desired location and attach it securely by connecting 
the side supports to the anchoring surface with two or three screws on 

each side.  (These screws are not included with the IVG-400.) 

 

IVG-400 Installation Instructions 

 

 

 

Page 3 of 7 

 

Summary of Contents for MVS-44

Page 1: ... LA AT TI IO ON N I IN NS ST TR RU UC CT TI IO ON NS S 11 Hartom St Jerusalem 91450 Israel PO 434 Milford NJ 08848 USA Tel 972 2 535 0000 Fax 972 2 586 8683 Tel 1 908 995 4383 Fax 1 888 681 8218 E mail info servision net www servision net E mail maxe servision net ...

Page 2: ...Hardware Requirements 1 Selecting a Location 2 Power Connection and Usage 2 Installing the IVG 400 3 Connecting a Camera 4 Connecting a Sensor 4 Connecting an Alarm 5 Connecting an Alarm in Release 1 5 Connecting an Alarm in Release 2 6 Copyright Copyright 2005 All Rights Reserved ...

Page 3: ...controlled remotely through the IVG 400 This document explains how to install the IVG 400 in a vehicle Connection Diagram The following diagram indicates where the various connectors are located on the IVG 400 unit Figure 1 Connection diagram Hardware Requirements The following hardware is included with the IVG 400 1 Two side supports 2 Six screws to attach the side supports to the unit IVG 400 In...

Page 4: ...onnecting a sensor Two wires to connect the output to t IVG 400 dry contacts normally included with the sensor 3 Connecting an alarm 16 AWG red and black cable to connect the alarm to the IVG 400 and for release 1 to a relay For release 1 A 12VDC power relay such as the Fujitsu FTR MYAA012A Figure 3 Fujitsu FTR MYAA012A relay Selecting a Location IVG 400 should be placed in the coolest available l...

Page 5: ...ition is switched on and about 2 5 minutes after the ignition is switched off Installing the IVG 400 To install the IVG 400 1 Connect the two side supports Figure 4 to either side of the body of the IVG 400 using three screws for each support as in Figure 5 The screws are included with the IVG 400 Figure 4 Side support Figure 5 Side supports attached to IVG 400 body Screw Side support IVG 400 body...

Page 6: ...wer off the system without supplying a signal that informs about it e g switching off the ignition Connecting a Camera Up to four cameras can be connected to the IVG 400 To connect a camera to the unit 1 Install the camera in its desired location in the vehicle 2 Connect the video output of the camera to a VideoIn connector on the rear panel of the IVG 400 see Figure 1 page 1 3 Optional If the cam...

Page 7: ...properly Release 1 of the IVG 400 does not have a built in relay To connect an alarm to a release 1 unit you must acquire a relay and connect it externally In release 2 of the IVG 400 the relay is built into the unit Instructions for connecting an alarm with or without a built in relay are provided below Connecting an Alarm in Release 1 To connect an alarm to a release 1 unit which does not have a...

Page 8: ... the same right contact of the output connection e g Out1 in the Activators terminal block Figure 8 Connecting an alarm to the IVG 400 release 1 IVG 400 Installation Instructions Page 6 of 7 Connecting an Alarm in Release 2 To connect an alarm to a release 2 unit which has a built in relay 1 Install the alarm in its desired location in the vehicle 2 Connect the alarm to the Activators terminal blo...

Page 9: ...e Connect the other side of the alarm to the left connection e g Out1 in the terminal block Connect the negative power to the right cont output connection in the terminal block Figure 9 Connecting an alarm to the IVG 400 release 2 Out1 Out2 Activators 12V er Alarm Pow IVG 400 rear panel terminal block ...