NetworX Series

  

NX-591E Cellemetry Module 

 

 

Installation and Startup

Summary of Contents for NetworX Series

Page 1: ...NetworX Series NX 591E Cellemetry Module Installation and Startup ...

Page 2: ...STRUCTIONS 11 Location 0 Programming the Mode 11 Location 1 Feature Selection 11 Loc 2 7 When Phone Fault Is Detected 12 Location 2 Events To Report To Central Station 12 Location 3 Special Events To Report To Central Station 12 Location 4 Events To Report To Email 13 Location 5 Special Events To Report To Email 13 Location 6 Events To Report To Pager 13 Location 7 Special Events To Report To Page...

Page 3: ...messages to be reported keeping airtime to a minimum The NX 591E has 14 LEDs to provide extensive diagnostic and setup information II ACTIVATION VIA WEBSITE The cellemetry unit can be activated and managed via our web site address www gesecurity com cellemetry If your company already has an account set up proceed to step 1 below Otherwise you must first set up a dealer account 1 At the bottom of t...

Page 4: ...ce that the insertion points have two sizes of holes a larger hole and a smaller hole Diagram 1 The black plastic PCB guides are grooved on one edge where the PC Board will be seated The end with the half moon protrusion fits into the larger hole The smaller hole is for the screw Diagram 2 Place the first black plastic PCB guide in the top insertion point grooved edge downward The half moon protru...

Page 5: ...ess takes about 12 seconds during which time the AService LED will illuminate When using the LCD Keypad the Service Required message will be displayed User codes will not be accepted during the enrolling process Once a module is enrolled if the control panel does not detect it the AService LED will illuminate VI WIRING THE MODULE MAXIMUM WIRE RUN LENGTH IN FEET WIRE GAUGE Connected To NX Control P...

Page 6: ...ket to tower Flashing Waiting for acknowledgement DS6 ON Sending data message to tower Flashing Waiting for acknowledgement XMIT Message packet being transmitted to tower POOR FAIR GOOD BEST The LEDs will either be Off On Flashing slow or Flashing Fast depending on the dB of the signal Refer to Table VIII 2 for details SVC Cellular service available SVC2 Two or more control channels available RXD ...

Page 7: ...NX 591E 7 IX CONNECTION DIAGRAM ...

Page 8: ...ed 3 Factory Defaulting the Module The keypad will beep 3 times indicating that the loading is in progress Remember you will erase any values you may have entered previously 4 Programming a Location Once the number of the module to be programmed has been entered the Armed LED will illuminate while it is waiting for a programming location to be entered If an attempt is made to program an invalid en...

Page 9: ...uish The Armed LED will illuminate waiting for a new programming location to be entered To Review The Data location The Armed LED will flash If the location number is valid the Armed LED will extinguish the Ready LED will illuminate and the zone LEDs will show the binary data for the first segment of this location Do not enter data The next segment is displayed Each time r is pressed the data of t...

Page 10: ...Once the data is programmed press r to enter the data and advance to the next segment of that location After the last segment of a location is programmed pressing r will exit that location turn the Ready LED off and the Armed LED on As before you are now ready to enter another programming location If an attempt is made to program a number too large for a particular segment the keypad sounder will ...

Page 11: ...Disable Cellular Service LEDs Disabled Enabled 7 Enable Tamper Switch Enabled Disabled 8 Disable SIA DCS Area Modifier Disabled Enabled Segment 2 programs for Host Acknowledgement requirements Factory default for all options is OFF Option Description ON OFF 1 Central Station messages Enabled Disabled 2 Email messages Enabled Disabled 3 Pager messages Enabled Disabled 4 Periodic test signals Enable...

Page 12: ...EGMENT DESCRIPTION 1 Alarms 9 Tampers 2 Open Close 10 Short Circuit Ground Fault 3 Bypass 11 Sensor Lost 4 Zone Trouble 12 Sensor Low Battery 5 Power Trouble AC Failure or Low Battery 13 Expander Trouble 6 Siren Telephone Fault 14 Failure To Communicate 7 Test Reports 15 Zone Activity Monitor 8 Program Download Log Full 16 Reserved Location 3 Special Events To Report To Central Station Phone fault...

Page 13: ...Special Events To Report To Email Phone fault detected 8 segments of Feature Selection Data This location selects the partition s to include when reporting Special Events to email To exclude any partition from reporting simply turn off the LED corresponding to that particular partition Using Table XI 1 on page 12 enter the corresponding number of the partition s to include for each type of report ...

Page 14: ...Special Events To Report To Pager Phone fault detected 8 segments of Feature Selection Data This location selects the partition s to include when reporting Special Events to a pager To exclude any partition from reporting simply turn off the LED corresponding to that particular partition Using Table XI 1 on page 12 enter the corresponding number of the partition s to include for each type of repor...

Page 15: ...pecial Events To Report To Central Station Phone line is good 8 segments of Feature Selection Data This location selects the partition s to include when reporting Special Events to the Central Station when the phone line is good To exclude any partition from reporting simply turn off the LED corresponding to that particular partition Using Table XI 1 on page 12 enter the corresponding number of th...

Page 16: ...artitions OFF SEGMENT DESCRIPTION 1 Alarm Restores 2 Telephone Fault 3 Start Download 4 Fail to Communicate Data Lost 5 8 Reserved Location 12 Events To Report To Pager Phone line is good 16 segments of Feature Selection Data Reporting must be enabled in the control panel for this location to function properly This location selects the partition s to include when reporting to a pager when the phon...

Page 17: ...ine is good To exclude any partition from reporting simply turn off the LED corresponding to that particular partition Using Table XI 1 on page 12 enter the corresponding number of the partition s to include for each type of report found in Segments 1 8 Factory default is all partitions OFF SEGMENT DESCRIPTION 1 Alarm Restores 2 Telephone Fault 3 Start Download 4 Fail to Communicate Data Lost 5 8 ...

Page 18: ...difier OFF 2 HOST ACKNOWLEGEMENT REQUIRED 1 Host Ack for Central Station messages OFF 2 Host Ack for email messages OFF 3 Host Ack for pager messages OFF 4 Host Ack for periodic test signals OFF 5 8 Reserved 3 4 Reserved LOC PG SEG DESCRIPTION PARTITION 2 12 REPORTING EVENTS TO CENTRAL STATION Phone line fault detected 1 2 3 4 5 6 7 8 1 Alarms 2 Open Close 3 Bypass 4 Zone Trouble 5 Power Trouble A...

Page 19: ...4 5 6 7 8 1 Alarms 2 Open Close 3 Bypass 4 Zone Trouble 5 Power Trouble AC Fail or Low Battery 6 Siren Telephone Fault 7 Test Reports 8 Program Download Log Full 9 Tampers 10 Short Circuit Ground Fault 11 Sensor Lost 12 Sensor Low Battery 13 Expander Trouble 14 Fail to Communicate 15 Zone Activity Monitor 16 Reserved 5 13 REPORTING SPECIAL EVENTS TO EMAIL Phone line fault detected 1 2 3 4 5 6 7 8 ...

Page 20: ...ne Activity Monitor 16 Reserved 7 14 REPORTING SPECIAL EVENTS TO PAGER Phone line fault detected 1 2 3 4 5 6 7 8 1 Alarm Restores 2 Telephone Fault 3 Start Download 4 Fail to Communicate Data Lost 5 8 Reserved 8 15 REPORTING EVENTS TO CENTRAL STATION Phone line is good 1 2 3 4 5 6 7 8 1 Alarms 2 Open Close 3 Bypass 4 Zone Trouble 5 Power Trouble AC Fail or Low Battery 6 Siren Telephone Fault 7 Tes...

Page 21: ... 6 7 8 1 Alarms 2 Open Close 3 Bypass 4 Zone Trouble 5 Power Trouble AC Fail or Low Battery 6 Siren Telephone Fault 7 Test Reports 8 Program Download Log Full 9 Tampers 10 Short Circuit Ground Fault 11 Sensor Lost 12 Sensor Low Battery 13 Expander Trouble 14 Fail to Communicate 15 Zone Activity Monitor 16 Reserved 11 16 REPORTING SPECIAL EVENTS TO EMAIL Phone line is good 1 2 3 4 5 6 7 8 1 Alarm R...

Page 22: ... 6 Siren Telephone Fault 7 Test Reports 8 Program Download Log Full 9 Tampers 10 Short Circuit Ground Fault 11 Sensor Lost 12 Sensor Low Battery 13 Expander Trouble 14 Fail to Communicate 15 Zone Activity Monitor 16 Reserved 13 17 REPORTING SPECIAL EVENTS TO PAGER Phone line is good 1 2 3 4 5 6 7 8 1 Alarm Restores 2 Telephone Fault 3 Start Download 4 Fail to Communicate Data Lost 5 8 Reserved ...

Page 23: ...one LED Horizontal Keypad NX 8E KIT NX 8E Control NX 108E Keypad 40VA Transformer NX 148E Alphanumeric LCD Keypad NX 8E KIT 8 NX 8E Control NX 1448E Keypad 40VA Transformer NX 1308E 8 Zone LED Door Design Keypad NX 8E NX 8E Control Only NX 1316E 16 Zone LED Door Design Keypad NX 8 KIT NX 8 Control NX 108E Keypad 40VA Transformer NX 1324E 24 Zone LED Door Design Keypad NX 8 NX 8 Control Only NX 144...

Page 24: ...LEDs enabled 90mA Max Transmission Burst 1 second 1300mA Max OPERATING TEMPERATURE 32 to 120 degrees F DIMENSIONS 2 40 Wide 4 40 High 1 20 Deep SHIPPING WEIGHT 1 lb Main Phone 800 727 2339 Technical Support 888 437 3287 Outside the US 903 845 6941 Sales Literature 800 547 2556 Main Fax 903 845 6811 Web www gesecurity com NX591E INSTALLATION MANUAL NX591EIE05 REV E May 2005 ...