NX-1348E-ICON
- 14 -
g
GE Interlogix
OTHER KEYPAD FUNCTIONS
Setting the keypad tone
Step 1
Press [
r
]-[
0
]. Keypad is now in the “Adjust Tone” mode.
Step 2
Pressing the [
•
] key will make the keypad sounder go to higher tones, pressing the [
–
] key will make the
keypad sounder go to lower tones.
Step 3
When the desired tone is reached, press the [
#
] key to set this tone and exit from the “Adjust Tone” mode.
Change partition (optional)
Step 1
Press [
r
]-[
1
].
Step 2
Press a NUMBER key between 1 and 8 to change partitions momentarily.
Step 3
If no other key is pressed, it will go back to its standard partition in ten seconds.
Step 4
If another key is pressed, the system will remain in the new partition until no keys have been pressed for 60
seconds.
View alarm memory
Step 1
Press [
r
]-[
3
]. The zone(s) that created the last alarm will be displayed along with the alarm icon flashing on
the keypad.
Step 2
The
ALARM MEMORY
feature will flash those zones that created alarms and will display steady those zones
that were bypassed during the last alarm.
Test function (optional)
If programmed, this function will perform a battery test, communicator test, and/or a siren test. Alarms and reports will
not be sent, unless a communicator test is performed at which time a test signal will be sent.
Step 1
Press [
r
]-[
4
]. The test will be performed as programmed.
Step 2
If the siren test is performed, enter a user code to silence the siren.
Reset function
This function is used to reset Smoke Detectors and Zone Troubles. Your system must be
Disarmed
to use the Reset
function.
Step 1
Press [
r
]-[
7
]. Resets
have now been performed.
Step 2
If the keypad begins beeping, the reset did not execute properly. Enter your code to silence the keypad. Wait a
few minutes and repeat step 2 to attempt another reset. If the keypad still beeps after repeated attempts, please
contact your installer.